6.1 Schedule of Function Parameters
6.1 Schedule of Function Parameters
Function
Code
Name
Setting Range
Unit
Min.
Unit
Default
Setting
Operation
Modification
Function
Code
Name
Setting Range
Unit
Min.
Unit
Default
Setting
Operation
Modification
6.1.3 F2 Series Auxiliary Operation Parameters
Starting mode selection
Starting frequency
Starting frequency
sustain time
Starting DC braking current
Starting DC braking time
Acceleration/Deceleration mode
selection
S curve initial section
time ratio
S curve rise/fall section
time ratio
AVR function selection
Auto energy saving
operation selection
FWD/REV dead time
Stop mode selection
Stop DC braking
initial frequency
Stop DC braking current
Stop DC braking time
Power cut restarting
selection
Power cut restarting
wait time
Failure auto reset times
0: Start with initial frequency.
1: Start with rotary speed tracing.
0.0: Braking inaction
0: Linear acceleration/deceleration
1: S curve acceleration/deceleration
0: Disabled 1: Enabled
0: Disabled 1: Enabled
0: Accelerated stop
1: Free stop
0: Disabled
1: Regular start
2: Start with rotary speed tracing
0.0: Braking inaction 0.1~30.0s
6.1.3 F2 Series Auxiliary Operating Parameters (Continuation
)
Failure auto reset interval
time
JOG operation frequency
setting
JOG acceleration time
setting
JOG deceleration time
setting
Acceleration time 2
Deceleration time 2
Acceleration time 3
Deceleration time 3
Acceleration time 4
Deceleration time 4
1st stage speed output
frequency
2nd stage speed output
frequency
3rd stage speed output
frequency
4th stage speed output
frequency
5th stage speed output
frequency
6th stage speed output
frequency
7th stage speed output
frequency
Remain
Leap frequency 1
Range of leap frequency 1
Leap frequency 2
Note: The default unit is "second".
Refer to F3.09 for unit selection.
Note: The default unit is "second".
Refer to F3.09 for unit selection.
Note: The default unit is "second".
Refer to F3.09 for unit selection.
Note: The default unit is "second".
Refer to F3.09 for unit selection.
0.00 ~ upper limit frequency
0.00 ~ upper limit frequency
0.00 ~ upper limit frequency
0.00 ~ upper limit frequency
0.00 ~ upper limit frequency
0.00 ~ upper limit frequency
0.00 ~ upper limit frequency
0.00 ~ upper limit frequency
0.00 ~ upper limit frequency
0.00 ~ 10.00Hz
According to
specification
According to
specification
According to
specification
According to
specification
According to
specification
According to
specification
According to
specification
According to
specification