Control Setup
Chore-Tronics® 3 Control
63
MT2398C
RH (Relative Humidity) Settings
1. Select the Main menu button.
Select the
Ventilation Settings button.
2. Select the RH Influence button.
3.
Actual Influence
- The actual amount of
influence time the RH function is adding to
the minimum ventilation timer. The con-
trol may not always add the full amount of
time if the amount of influence would add
up to be more than the maximum allowed
setup in the (Ventilation Settings/Set
Temp) screen.
5.
Low Control Limit
- If the RH in the house is below this setting than the control will
subtract an increment of on time to the minimum ventilation timer down to the minimum
setting is (Ventilation Settings/Set Temp) screen.
Note:
If the RH is between the High and Low Control limit, then the control will neither
add or subtract on time to the minimum ventilation timer. The RH is check 30 seconds
prior to an ON time cycle of the minimum ventilation timer.
4.
High Control Limit
- If the RH in the
house is above this setting than the control will add
an increment of on time to the minimum ventilation timer up to the maximum amount of
influence allowed or the maximum possible amount of ventilation on time that is set in the (Ventilation
Settings/Set Temp) screen.
3
4
5
Содержание Chore-Tronics 3 Control
Страница 1: ...Chore Tronics 3 Control Installation Operator s Instruction Manual MT2398C November 2013...
Страница 124: ...Wiring Diagrams Chore Tronics 3 Control 124 MT2398C Fan Wiring Figure 45 Fan Wiring...
Страница 127: ...Chore Tronics 3 Control Wiring Diagrams MT2398C 127 This page left blank intentionally...
Страница 128: ...Wiring Diagrams Chore Tronics 3 Control 128 MT2398C Brooder Wiring...
Страница 129: ...Chore Tronics 3 Control Wiring Diagrams MT2398C 129...
Страница 133: ...Chore Tronics 3 Control Improving Lightning Surge Suppression MT2398C 133 This page left blank intentionally...
Страница 141: ...Chore Tronics 3 Control Technical Specifications MT2398C 141 This page left blank intentionally...