Chore-Tronics® 3 Control
Control Installation
MT2398C
103
Airspeed Sensor Wiring
The Airspeed Sensor requires a three conductor wire to connect the Sensor to one of the Digital (DI)
Inputs on the IO board. It is recommended that the digital input chosen is adjacent to one of the 12 volt
outputs on the IO board
(Figure 31)
. The Brown wire on the Sensor needs to be connected to the +12 volt
output, the Green wire on the Sensor needs to be connected to the ground terminal of the digital input
being used, and the White wire needs to be connected to the DI(x) terminal of the digital input being used.
DI1
12V
2
(DI) of your Choice
Item
Description
1
Airspeed Sensor
2
I/O Board Digital Input (DI)
terminal of your Choice
Figure 31. Airspeed Sensor Wiring
1
GREEN
BROWN
WHITE
Feed Scale Wiring
If one or more Feed Scales are used, they need to be connected to one of the Digital (DI) Inputs on the IO
board using Twisted Pair Wire. Connect the switch located on the side of the Feed Scale to the IO Board
using the blue and brown wires
(Figure 32)
. See manual MT1811 for more information.
Item
Description
1
Feed Scale
2
I/O Board Digital Input (DI)
terminal of your Choice
Figure 32. Feed Scale Wiring
2
(DI) of your Choice
1
DI1
12V
Содержание Chore-Tronics 3 Control
Страница 1: ...Chore Tronics 3 Control Installation Operator s Instruction Manual MT2398C November 2013...
Страница 124: ...Wiring Diagrams Chore Tronics 3 Control 124 MT2398C Fan Wiring Figure 45 Fan Wiring...
Страница 127: ...Chore Tronics 3 Control Wiring Diagrams MT2398C 127 This page left blank intentionally...
Страница 128: ...Wiring Diagrams Chore Tronics 3 Control 128 MT2398C Brooder Wiring...
Страница 129: ...Chore Tronics 3 Control Wiring Diagrams MT2398C 129...
Страница 133: ...Chore Tronics 3 Control Improving Lightning Surge Suppression MT2398C 133 This page left blank intentionally...
Страница 141: ...Chore Tronics 3 Control Technical Specifications MT2398C 141 This page left blank intentionally...