Control Setup
Chore-Tronics® 3 Control
36
MT2398C
Setup House
1. Select the Main menu button.
Select the
Setup button
from the Main
Menu screen. Finally, select the
House
Button.
2. In this Screen you set what type of ventilation
is being used in the House.
3.
Temp. Influence on Minimum Ventilation.
Select this box if you want the Min. Vent Timer
to ramp up & down based on temperature.
See
explanation and example below.
Ventilation timer ramping-
If the sensor(s) that are assigned to the Minimum Ventilation fan(s) tem-
perature is at or below set temperature then the fans will use the ON and OFF times that are listed for
the Minimum Ventilation Timer. If the sensor (s) assigned to the Ventilation Time Ramping tempera-
ture is between set temperature and the fans' ON temperature the control will adjust the amount of ON
time between the Min Ventilation value and the Max value. The OFF time will be adjusted by the same
amount of time that the ON is adjusted, thus keeping the total cycle time constant. The temperature is
checked 30 seconds before the beginning of the ON time cycle of the Minimum Ventilation Timer.
Once the fans' temperature sensor(s) reach the fans' ON temperature, the fan will turn on and run con-
tinuously until the fans' OFF temperature is reached.
Example:
The set temperature is 70.0°F and the fans assigned to the Min Vent timer ON temperature is 72.0°F.
The Minimum Ventilation Timer values are 30 seconds ON time and 270 seconds OFF time. The max-
imum ON time is 210 seconds. If the sensor(s) assigned to the Ventilation Time Ramping temperature
is 71.0°F at the beginning of the anticipation cycle, then the fans will have an ON time of 125 seconds
and an OFF time of 175 seconds.
4.
Mortality
Select this box if you want to keep track of the
Mortality. To separate male and female select
Separate Male Female.
Содержание Chore-Tronics 3 Control
Страница 1: ...Chore Tronics 3 Control Installation Operator s Instruction Manual MT2398C November 2013...
Страница 124: ...Wiring Diagrams Chore Tronics 3 Control 124 MT2398C Fan Wiring Figure 45 Fan Wiring...
Страница 127: ...Chore Tronics 3 Control Wiring Diagrams MT2398C 127 This page left blank intentionally...
Страница 128: ...Wiring Diagrams Chore Tronics 3 Control 128 MT2398C Brooder Wiring...
Страница 129: ...Chore Tronics 3 Control Wiring Diagrams MT2398C 129...
Страница 133: ...Chore Tronics 3 Control Improving Lightning Surge Suppression MT2398C 133 This page left blank intentionally...
Страница 141: ...Chore Tronics 3 Control Technical Specifications MT2398C 141 This page left blank intentionally...