– 20 –
6. Repeat steps 2–4 on the second test point/location.
7. Press the
key to display the calculated velocity edit screen.
NOTE:
The calculated velocity can be edited, if needed, by pressing the
keys to scroll and edit the velocity value.
8. Press the
key to set the calculated material velocity and return to the
measurement screen.
NOTE:
CHECK YOUR CALIBRATION! Place the transducer back on the calibration
points. The thickness readings should now match the known thickness values with
minimal error. If the thicknesses are not correct, repeat the steps above.
Basic Material Type
If the material velocity is unknown, a sample thickness cannot be taken directly from
the material, but the general type of material is known, selecting a basic material type
from the common material (MATL) list in the TI-007DLX would offer a reasonable
approximation of the thickness. There are 9 common materials and 2 user programmable
settings available. It’s important to note that these velocities will not always be an
exact representation of the material being tested. Use these values only if a close
approximation is acceptable. Follow the steps below to select a basic material type:
Selecting a Basic Material Type
1. Press the
key to access the menu items/features
2. Use the
and
keys to scroll through the items/features until the
MATL
feature is being displayed.
3. Press the
key to edit the material setting. The edit icon will be illuminated
and flashing.
NOTE:
Pressing the
key prior to pressing the
key will abort to the
measurement screen without saving any changes.