100
Af
st
ellen
ARIANE
X
T
PL
US
MENU
SUBMENU
P
A
R
AME
TER
BESCHRIJVING
BEREIK
FABRIEKSINSTELLING
5
4
2
Constante snelheid van de pomp
100
5
5
Cooling
5
5
0
T set cool Z2
7°C [FC] - 18°C [Pavimento]
5
5
1
Zone 1 Cooling Temp Range
Fan Coil
UFH
Fan Coil
5
5
2
Thermoregulation type
ON/OFF
Fix Flow T
Outdoor T Only
ON/OFF
5
5
3
Slope
[18;33] FC; [0-30] Pavimento
25 FC; 10 Pavimento
5
5
4
Offset
[-2,5°C; +2,5°C]
0
5
5
6
Max T
MinT -12°C [FC];
MinT - 23°C [Pavimento]
12°C [FC];
23°C [Pavimento]
5
5
7
Min T
7°C-MaxT [FC]; 18-MaxT [UFH]
7°C [FC];
18°C [Pavimento]
5
5
8
Target deltaT for pump modulation cooling
[-5; -20°C]
-5°C
6
5
Cooling
7
MODULE ZONES
UIT - AAN
7
1
Manuele Modus
UIT - AAN
7
1
0
Manuele Modus activeren
UIT - AAN
7
1
1
Controle Pomp Zone 1
UIT - AAN
7
1
2
Controle Pomp Zone 2
UIT - AAN
UIT
7
1
4
Controle Mengklep Zone 2
OFF
Open
gesloten
OFF
7
2
Algemene Module Zones
7
2
0
Bepalen hydraulisch schema
Niet bepaald
MCD
MGM II
MGM III
MGZ I
MGZ II
MGZ III
MGM II
7
2
1
Verschuiving aanvoertemperatuur
0
7
2
2
Instelling Aux. Uitgang
Vraag naar verwarming
Externe pomp
Alarm
Vraag naar verwarming
7
2
3
Correctie buitentemperatuur
0
7
3
Cooling
0
7
3
0
Flow_T_offset_Cool [0-6°C]
7
8
Historiek van de foutmeldingen
7
8
0
10 laatste foutmeldingen
7
8
1
Reset de lijst met foutmeldingen
Reset? OK=ja, Esc=neen
7
8
2
10 laatste foutmeldingen 2
7
8
3
Reset de lijst met foutmeldingen 2
Reset? OK=ja, Esc=neen
7
9
Reset Menu
7
9
0
Reset de standaardinstellingen
Reset? OK=ja, Esc=neen
17
PARAMETERS warmtepompsysteem
17
0
Gebruikersparameters