64
R
egulation
ARIANE
X
T
PL
US
MENU
SUB-
MENU
PA
R
AME
TER
DESCRIPTION
RANGE
DEFAUTL
0
NETWORK
0
2
BUS network
0
2
0
Network presence
System interface
Energy Manager
Heat Pump
Room Sensor
Zone Manager
0
3
System interface
0
3
0
Zone number
No zone selected
Zone selected
0
3
1
Room temperature correction
1
0
3
2
SW Version Interface
4
ZONE1 PARAMETERS
4
0
Setpoint
4
0
0
T Day
19
4
0
1
T Night
16
4
0
2
T set Z1
20 (LT) - 40 (HT)
4
0
3
Zone frost temperature
5
4
1
Free parameters
4
2
Z1 Settings
4
2
0
Zone 1 temperature range
Low Temp
High Temp
Low Temp
4
2
1
Thermoregulation
Fix Flow T
Basic Thermoreg
Room T Only
Outdoor T Only
Room+Outdoor T
Basic Thermoreg
4
2
2
Slope
1,5
4
2
3
Offset
0
4
2
4
Room Infl uence Proportional
20 (LT) - 10 (HT)
4
2
5
Max T
45 (LT) - 60 (HT)
4
2
6
Min T
20 (LT) - 20 (HT)
4
3
Z1 Diagnostics
4
3
0
Room T
4
3
1
Room T setpoint
4
3
2
Flow temperature
4
3
3
Return temperature
4
3
4
Heat Request Z1
OFF - ON
4
3
5
Pump Status
OFF - ON
4
4
Z1 Zone Module Settings
4
4
0
Zone pump modulation
Fixed
Modulating on DeltaT
Modulating on Pressure
Modulating on DeltaT
4
4
1
Target deltaT for pump modulation
7 (LT) - 20 (HT)
4
4
2
Pump fi xed speed
100
4
5
Coolig
4
5
0
T Set Cool Z1
7°C [FC] - 18°C [Pavimento]
4
5
1
Zone 1 Cooling Temp Range
Fan Coil
UFH
Fan Coil
4
5
2
Thermoregulation type
ON/OFF
Fix Flow T
Outdoor T Only
ON/OFF
4
5
3
Slope
[18;33] FC; [0-30] Pavimento
25 FC; 10 Pavimento
4
5
4
Offset
[-2,5°C; +2,5°C]
0
4
5
6
Max T
MinT -12°C [FC];
MinT - 23°C [Pavimento]
12°C [FC];
23°C [Pavimento]
4
5
7
Min T
7°C-MaxT [FC]; 18-MaxT [UFH]
7°C [FC];
18°C [Pavimento]
4
5
8
Target deltaT for pump modulation cooling
[-5; -20°C]
-5°C