46
Technische eigenschappen
ARIANE
X
T
PL
US
MODEL
12 kW
15 kW
12 T kW
15 T kW
air to water heat pump
SI
with supplementary heater
SI
Rated heat output
[kW]
8,82
9,20
8,51
9,52
Annual energy consumption
[%]
6387
5928
5332
6043
Seasonal space heating energy effi
ciency
[%]
111
125
128
127
Sound power level, outdoor
[dB]
67
68
68
68
Sound power level, indoor (1 zona)
[dB]
48
Declared capacity and coeffi
cient of performance for heating at indoor conditions 20°C and outdoor temperature Tj
Climate
Average
Bivalent temperature
[°C]
-7
Operating limit temperature
[°C]
-20
Heating water operation limit temperature
[°C]
60
Capacità
COPd
Capacità
COPd
Capacità
COPd
Capacità
COPd
Tj = -7 °C
[kW]
7,08
1,99
8,14
2,04
7,53
1,98
8,42
1,90
Tj = 2 °C
[kW]
4,53
3,02
5,10
3,05
5,55
3,36
5,46
3,33
Tj = 7 °C
[kW]
2,94
4,14
3,59
4,33
3,55
4,38
3,36
4,10
Tj = 12 °C
[kW]
2,57
5,71
3,13
6,02
4,03
5,93
2,90
5,37
Tj = biv
[kW]
7,08
1,99
8,14
2,04
7,53
1,98
8,42
1,90
Tj = Operating limit temperature
[kW]
6,73
1,80
7,73
1,84
7,15
1,79
8,00
1,72
Degradation coeffi
cient
Tj = -7 °C
0,90
Tj = 2 °C
Tj = 7 °C
Tj = 12 °C
Consumo energetico in modi diversi dal modo attivo
Off mode
[kW]
0
0
0
0
Thermostat-off mode
[kW]
0,084
0,092
0,088
0,09
Standby mode
[kW]
0,05
0,05
0,05
0,05
Crankcase heater mode
[kW]
0,05
0,05
0,05
0,05
Apparecchio di riscaldamento supplementare
Rated heat output (**)
[kW]
4
Type of energy input
Electric
For heat pump combination heater
Declared load profi le
XL
XXL
XXL
XXL
Daily electricity consumption
10,341
10,341
10,341
10,341
Annual electricity consumption
2271
2271
2271
2271
Water heating energy effi
ciency
95
95
95
95
Other items
Capacity control
Variable
Outlet temperature capacity control
Variable
Water fl ow rate capacity control
Fixed
Per pompe di calore aria/acqua
Rated Air fl ow rate, outdoor.
[m3/h]
6000
6200
6000
6200
TECNICAL DATA
The water heat exchanger fouling factor is 0 (m
2
K)/W for all conditions.
*
Standard Eurovent LCP/A/CHF conditions in heating mode: water heat exchanger entering/leaving water temperature 30 °C/35 °C, outside air temperature 7 °C db/6 °C wb.
Standard Eurovent LCP/A/CHF conditions in cooling mode: water heat exchanger entering/leaving water temperature 23 °C/18 °C, outside air temperature 35 °C.
** Standard Eurovent LCP/A/AC conditions in heating mode: water heat exchanger entering/leaving water temperature 40 °C/45 °C, outside air temperature 7 °C db/6 °C wb.
Standard Eurovent LCP/A/AC conditions in cooling mode: water heat exchanger entering/leaving water temperature 12 °C/7 °C, outside air temperature 35 °C.
*** Conditions in heating mode: entering/leaving water temperature 55 °C/a, outside air temperature 7 °C db/6 °C wb. Performances are in accordance with EN 14511.
**** Based on the following conditions: entering/leaving water temperature 35 °C/30 °C, outside air temperature 7 °C.
† Based on the following conditions: entering/leaving water temperature 12 °C/7 °C, outside air temperature 35 °C.
Note: The sound pressure level is measured in a hemisperic fi eld at 4 m distance from the unit.