48
Technische eigenschappen
ARIANE
X
T
PL
US
Technical data
Power supply
BUS
Electrical absorption
max. < 0,5W
Operating temperature
-10 ÷ 60°C
Storage temperature
-20 ÷ 70°C
Bus wire length and cross-sectional area
NOTE:
TO AVOID INTERFERENCE PROBLEMS,
USE A SHIELDED CABLE OR TWISTED
PAIR CABLE.
max. 50 m
min. 0.5 mm²
Buffer memory
2 h
Conformity
LVD 2006/95/EC - EMC 2004/108/EC
Electromagnetic interference
EN 60730-1
Electromagnetic emissions
EN 60730-1
Conformity to standards
EN 60730-1
Temperature sensor
NTC 5 k 1%
Resolution degree:
0,1°C
134 mm
16 mm
96 mm
SYSTEM INTERFACE
OUTDOOR SENSOR
Position the outdoor sensor on the north-facing wall of the
building, at least 2.5 m from the ground and away from direct
sunlight.
Remove the cover and install the sensor using the rawl plug
and screw provided. Perform connection using a 2x0.5 mm2
wire.
Maximum connection length 50 m. Connect the wire to the
terminal by introducing it from the lower part after creating a
suitable passage.
Place the sensor cover back in the correct position..
A
B
C
PRODUCT FICHE (valid from September 26th, 2015)
SUPPLIER’S NAME
Chaff oteaux
SUPPLIER’S MODEL IDENTIFIER
Expert Control
SONDA ESTERNA
Class of the temperature control
V
II
Contribution to seasonal space heating energy effi
ciency in %
+3%
+2%
Adding an Chaff oteaux OUTDOOR SENSOR:
Class of the temperature control
VI
--
Contribution to seasonal space heating energy effi
ciency in %
+4%
--
In a 3-zones system with 2 Chaff oteaux ROOM SENSORS
Class of the temperature control
VIII
--
Contribution to seasonal space heating energy effi
ciency in %
+5%
--