background image

33 

Technical data

 

 

 

 

 

3-phase mains connection 400 V  

Rated data 

 

 

 

6.3

 

3-phase mains connection 400 V

 

6.3.1

 

Rated data

 

The output currents apply to these operating conditions: 

• 

At a switching frequency of 2 kHz or 4 kHz: Max. ambient temperature 45°C. 

• 

At a switching frequency of 8 kHz or 16 kHz: Max. ambient temperature 40 °C. 

 

Inverter

 

 

DSV35401P3

 

DSV35401P8

 

DSV35402P4

 

DSV35403P2

 

DSV35403P9

 

DSV35405P6

 

Rated power

 

kW

 

0.37

 

0.55

 

0.75

 

1.1

 

1.5

 

2.2

 

Mains voltage range 

 

3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz 

Rated mains current 

 

 

without mains choke 

1.8 

2.5 

3.3 

4.4 

5.4 

7.8 

with mains choke 

1.4 

2.6 

3.7 

5.3 

Output current 

 

 

2 kHz 

1.8 

2.4 

3.2 

3.9 

5.6 

4 kHz 

1.3 

1.8 

2.4 

3.2 

3.9 

5.6 

8 kHz 

1.3 

1.8 

2.4 

3.2 

3.9 

5.6 

16 kHz 

0.9 

1.2 

1.6 

2.1 

2.6 

3.7 

Power loss 

24 

31 

40 

51 

61 

85 

Overcurrent cycle 180 s 

 

 

Max. output current 

1.95 

2.7 

3.6 

4.8 

5.85 

8.4 

Overload time 

60 

60 

60 

60 

60 

60 

Recovery time 

120 

120 

120 

120 

120 

120 

Max. output current 
during the recovery time 

0.975 

1.35 

1.8 

2.4 

2.93 

4.2 

Overcurrent cycle 15 s 

 

 

Max. output current 

2.6 

3.6 

4.8 

6.4 

7.8 

11.2 

Overload time 

Recovery time 

12 

12 

12 

12 

12 

12 

Max. output current 
during the recovery time 

0.975 

1.35 

1.8 

2.4 

2.93 

4.2 

Brake chopper 

 

 

Max. output current 

1.86 

1.86 

1.86 

4.03 

4.03 

4.83 

Min. brake resistance 

Ω

 

390 

390 

390 

180 

180 

150 

Motor cable length 

 

 

shielded, without EMC 

15 

50 

C1 residential area (2 kHz, 
4 kHz, 8 kHz) 

C2 residential area / 
industrial premises 

15 

20 

Weight 

kg 

0.8 

1.35 

Содержание Emotron DSV15

Страница 1: ...Emotron DSV15 35 AC drive 0 25 2 2 kW Mounting and switch on instruction...

Страница 2: ...This page intentionally left blank...

Страница 3: ...ns connection 400 V 16 4 3 2 1 Fusing and terminal data 17 4 3 3 Connection to the IT system 18 4 3 4 CANopen 19 4 3 5 Modbus 20 4 3 6 PROFIBUS 21 4 3 7 EtherCAT 22 4 3 8 EtherNet IP 23 4 3 9 PROFINET...

Страница 4: ...g Please observe the safety instructions 1 2 Notations and conventions 1 2 1 Product code examples DSV15 23 1P7 20 DSV35 40 1P3 20 DSV 15 23 1P7 20 Series 1 phase 230V Rated current 1 7A IP20 DSV 35 4...

Страница 5: ...not exceed 110 VDC Observe all specifications of the corresponding documentation supplied This is the precondition forsafe and trouble free operation and for obtaining the product features specified...

Страница 6: ...motor residual movement max 180 2 90 This residual movement must be taken into consideration by the user for his her risk assessment 2 3 Application as directed The product must only be operated unde...

Страница 7: ...7 Product description 3 3 Product description...

Страница 8: ...notes Dangerous electricalvoltage Possible consequence death or severeinjuries All works on the inverter must only be carried out in the deenergised state After switching off the mains voltage wait f...

Страница 9: ...9 Mounting Mechanical installation 4 4 2 Mechanical installation Dimensions 0 25 kW 0 37 kW All dimensions in mm...

Страница 10: ...10 4 Mounting Mechanical installation Dimensions 0 55 kW 0 75 kW All dimensions in mm...

Страница 11: ...11 Mounting Mechanical installation 4 Dimensions 1 1 kW 2 2 kW All dimensions in mm...

Страница 12: ...rical installation 1 phase mains connection 230 240 V 4 3 Electrical installation 4 3 1 1 phase mains connection 230 240 V The wiring diagram is valid for Emotron DSV15 35inverters COM NC NO Fig 1 Wir...

Страница 13: ...16 25 25 25 Circuit breaker Characteristic B Max ratedcurrent A 10 10 16 16 25 25 25 Earth leakage circuit breaker 30 mA type A or B Mains connection Connection X100 Connection type Screw terminal Min...

Страница 14: ...1 4 3 2 3 phase mains connection 400 V The wiring diagram is valid for Emotron DSV 35 inverters COM NC NO Fig 3 Wiring example S1 Run Stop Fx Fuses Q1 Mains contactor Dashed line options X105 U V W Rb...

Страница 15: ...10 16 16 16 Circuit breaker Characteristic B Max ratedcurrent A 10 10 10 16 16 16 Earth leakage circuit breaker 30 mA type B Mains connection Connection X100 Connection type Screw terminal Min cable c...

Страница 16: ...ts have earth ground potential if the IT screws are not removed Consequence the monitoring functions of the IT systemrespond Before connection to an IT system be absolutely sure to remove the IT screw...

Страница 17: ...a 64 32 16 8 4 2 1 OFF OFF ON OFF ON 20 kbps OFF OFF OFF OFF OFF OFF OFF Inactive OFF OFF ON ON 50 kbps Value fromparameter ON OFF OFF ON OFF 125 kbps Node address example Active OFF OFF OFF ON 250 k...

Страница 18: ...8 4 2 1 Mode Address Bus termina tion Baud rate Parity Modbus node address R c b a 128 64 32 16 8 4 2 1 OFF n c OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF Inactive Automatic detection Automatic detection...

Страница 19: ...RxD TxD N Data line A received data transmitted data 9 n c Basic networksettings Use the DIP switch to set the station address The baud rate is detectedautomatically Printed in bold CGsetting The net...

Страница 20: ...hernet 100 Mbps full duplex Use Connection of the inverter to an EtherCATnetwork Connectionsystem RJ45 Status display 2 LEDs Connection designation In X246 Out X247 Basic networksettings The rotary en...

Страница 21: ...thernet 10 Mbps 100 Mbps half duplex full duplex Use Connection of the inverter to an EtherNet IP network Connectionsystem RJ45 Status display 2 LEDs Connection designation X266 X267 Basic networksett...

Страница 22: ...I O controller SW Switch SCALANCE MRP capable D I O device R Redundant domain Bus related information Name PROFINET RT Communication medium Ethernet 100 Mbps full duplex Use Connection of the inverte...

Страница 23: ...the EN ISO 13849 2 If an external force acts upon the drive axes additional brakes are required Please observe that hanging loads are subject to the force ofgravity The user has to ensure that the inv...

Страница 24: ...onnection type Screw terminal Min cable cross section mm 0 5 Max cable cross section mm 1 5 Stripping length mm 6 Tightening torque Nm 0 2 Required tool 0 4 x 2 5 X1 Specification Unit min typ max SIA...

Страница 25: ...nstructions and safetyclearances 5 2 Before initial switch on Prevent injury to persons and damage to property Check the following before switching on the mains voltage Is the wiring complete and corr...

Страница 26: ...splays RDY and ERR on the front of the inverter a If the blue RDY LED is blinking and the red ERR LED is off the inverter is ready for operation The controller is inhibited You can now start the drive...

Страница 27: ...the function for the reversal of rotation direction again X3 DI3 LOW Speed characteristic example DI1 Drive follows frequencysetpoint AI1 V 10 0 DI4 Speed setpoint selection via X3 AI1 active t In th...

Страница 28: ...Overvoltage categoryIII EN 61800 5 1 0 2000 m a m s l Overvoltage categoryII above 2000 m a m s l Control circuit isolation Safe mains isolation by double reinforcedinsulation EN 61800 5 1 Protective...

Страница 29: ...torage 2K3 25 70 C EN 60721 3 2 Transport 3K3 10 55 C EN 60721 3 3 Operation Operation at a switching frequency of 2 or 4 kHz above 45 C reduce rated output current by 2 5 C Operation at a switching f...

Страница 30: ...2 6 7 9 6 4 kHz A 1 7 2 4 3 2 4 2 6 7 9 6 8 kHz A 1 7 2 4 3 2 4 2 6 7 9 6 16 kHz A 1 1 1 6 2 1 2 8 4 4 7 6 4 Power loss W 15 20 25 33 42 50 70 Overcurrent cycle 180s Max output current A 2 55 3 6 4 8...

Страница 31: ...3 9 5 6 4 kHz A 1 3 1 8 2 4 3 2 3 9 5 6 8 kHz A 1 3 1 8 2 4 3 2 3 9 5 6 16 kHz A 0 9 1 2 1 6 2 1 2 6 3 7 Power loss W 24 31 40 51 61 85 Overcurrent cycle 180s Max output current A 1 95 2 7 3 6 4 8 5 8...

Страница 32: ...02 2016 13500560 3 0 01 6229 01R1 CG Drives Automation Sweden AB M rsaregatan 12 Box 222 25 SE 250 24 HELSlNGBORG Sweden Tel 46 42 169900 info cgglobal com www emotron com...