![CG Emotron DSV15 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/cg/emotron-dsv15/emotron-dsv15_manual_2585390024.webp)
24
4
Mounting
Electrical installation
Connection of the safety module
4.3.10.2
Connection plan
Passive sensors
Active sensors
S1
safety switching device
S2
passive sensor
S1
active sensor - example lightgrid
4.3.10.3
Terminal data
Terminal description
Safety STO
Connection
X1
Connection type
Screw terminal
Min. cable cross-section
mm²
0.5
Max. cable cross-section
mm²
1.5
Stripping length
mm
6
Tightening torque
Nm
0.2
Required tool
0.4 x 2.5
X1
Specification
Unit
min.
typ.
max.
SIA, SIB
LOW signal
V
-3
0
+5
HIGH signal
V
+15
+24
+30
Running time
ms
3
Input current SIA
mA
10
14
Input current SIB
mA
7
12
Input peak current
mA
100
Tolerated test pulse
ms
1
Switch-off time
ms
50
Permissible distance of the test pulses
ms
10
GS
Reference potential for SIA and SIB