2
Preparation before use
2.1 Preparation before Operation
Step 3. Turn on the power switch on the front panel:
As shown in Fig. 2.3, do not connect any
equipment to the network analyzer before power-on. If everything is OK, power on the
instrument, and the indicator lamp on the power switch on the front panel will turn green.
2.1.3.2 Switching the instrument on/off
1) Power-on
Step 1.
Turn on the power switch of the rear panel (
“
|
”
);
Step 2
. Turn on the power switch in the lower left corner of the front panel, and the power indicator
lamp above the power switch will change from yellow to green.
Step 3.
The network analyzer will take about one minute to start up Windows 7 system, perform a
series of self-check and adjustment programs, and then start running the main measurement
program.
The instrument will in an operable state.
During cold start of the 3672 series vector network analyzer, preheat it for at least 30 minutes before
measurement to make it reach the specified performance indicators.
Analyzer running applications
The network analyzer will automatically run the applications after power on. If it exits from the
applications, rerun the measurement program by the following methods:
Method 1.
Click
[Start]
in the task bar in the lower left corner of the screen; point to
[Program]
in
the start men; point to
[Vector Network Analyzer]
in the program sub-menu; click
[Vector
Network Analyzer]
in the pop-up menu, and the analyzer will start running the
applications. The desktop shortcut icon can also be double clicked to run the applications.
Method 2.
Press down
[Preset]
key in the functional key area, and the analyzer will start running
applications of 3672 series vector network analyzer.
2) Switching off the instrument
Step 1
. Turn off the power switch on the bottom left of front panel. Then the analyzer goes into the
shut-down process (software and hardware may need some time to process before power-off)
and after several seconds, the analyzer powers off when the power indicator lamp above the
power switch turns from green to yellow;
Step 2.
Turn off the power switch on the rear panel (
“
O
”
), or disconnect the power supply of the
instrument.
The instrument is switched off.
图
2.1 3672
电源插座
图
2.2 3672
后面板电源开关
图
2.3 3672
前面板电源开关
Fig. 2.1 3672 Power Outlet
Fig. 2.2 3672 Rear Panel Power
Button
Fig. 22.3 3672 Front Panel Power
Button
NOTE