Technical manual

 Bio-Tec

Technical manual

 Bio-Tec

Thermal safety valve, steering of the boiler

Scheme 3.

 - 

Thermal protection in an closed heating system

1  - Heat exchanger connection
2  - Connecting point for the thermal safety 
       valve sensor
3  - Heat exchanger connection
4  - Thermal safety valve connection 
      (cold water inlet HV)
5  - Connecting point of the thermal safety valve 
      (to the boiler)
6  - Thermal safety valve-sensor
7  - Thermal safety valve

Safety air 
vent group

Inlet

Heat 

exchanger 

(factory

built in)

Sewage 
outlet

Filling/Draining

Outlet

6.0.  

STEERING OF THE BOILER

The boiler is steered by means of the electronic regulator (digital boiler regulation), 
which is built into the boiler on its upper side and has an steering and protecting 
function. The functions of the boiler regulations are described in the Point 7.0 and in 
Tecnical manual "Digital boiler regulation Bio-Tec".

2

10 11

12 13

14 15

3

4

1

5

6

7

8

9

Boiler regulation

7.0.  BOILER REGULATION

-   

Main switch (power supply switch) has the function to turn on / off the

    regulator.
-   LED display shows the measured temperatures, their ordinary number,
    number or parameter value as well as the regulator functioning mode signal.
-   Indication "START" (LED diode) shows the regulator functioning mode
    (ignition/operation).
-   "START"-button.
-   "P"-button.
-   "+"-button.
-   "-/STOP"-button.
-   "GLOW"-button.
-   Indication "GLOW" (LED diode). Indicates the active functioning of the burning
    process with glow keeping. This burning process mode can be turned on/off by
    pushing the button 8.
-   Indication "FUEL" (LED diode) indicates that after the period of the boiler
    warming up has run out, the flue gases temperature is under the setup level for
    burning with or without glow keeping. It is not recommended to open the boiler's
    door while the indication ''FUEL'' is NOT on.
-   Indication "FAN" (LED diode) indicates that the fan is turned on/off.
-   Indication "ERROR" (LED diode) indicates that the error appeared during the
    boiler functioning.
-   Indication "PUMP 1" (LED diode) indicates that the relay for the P1 supply is
    turned on/off.
-   Indication "PUMP 2" (LED diode) indicates that the relay for the P2 supply is
    turned on/off.
-   Indication "PUMP 3" (LED diode) indicates that the sanitary water pump is turned
    on/off.

4

1

5
6
7
8
9

2

10

11

12

13

14

15

3

Содержание Bio-Tec 25

Страница 1: ...lation volume IMPORTANT Open upper boiler door and close bottom if they open Put fine chopped wood to the top chamber on refractory stone chamotte over the burner nozzle so that the nozzle is not obst...

Страница 2: ...in boiler Exhaust gas temperature at nominal heat output Exhaust gas temperature at minimum heat output Exhaust mass flow at nominal heat output Exhaust mass flow at minimum heat output Standby heat l...

Страница 3: ...penings the flue gas chamber Upper opening for flue gas tube cleaning Lower refractory stone chamotte 2 parts Regulation of primary and secondary air Flue gas chamber with tubes and turbulators Poker...

Страница 4: ...boiler must be connected to the central heating system through the CAS water accumulators An integrated digital regulation system steers the functioning of the boiler steers the circulation pump integ...

Страница 5: ...ature This demand for moisture content is fulfilled with wood dried on air at least 12 months Fuel wood having moisture content to 20 max 25 minimum size bigger than a nozzle in refractory stone chamo...

Страница 6: ...be placed on the boiler and within the minimum distances shown in Figure 1 Image 1 Minimum distance from the room walls valid for closest tank to the wall Cleaning and mainternance of the boiler Clea...

Страница 7: ...tion principle the fuel burns out totally the cleaning of the boiler is limited to the upper and lower combusting chamber once in a week and the cleaning of flue gas tubes DC page 3 on the back side o...

Страница 8: ...NEY Properly calibrated and built chimney is the precondition for a safe operation of the boiler and economic heating The chimney has to be good insulated gas proof and smooth On the lower part of the...

Страница 9: ...air damper PZ page 3 for secondary and primary air if movable elements two lids of bottom openings of the flue gas chamber and flue gas tube cleaning lever Firing has to be performed according to the...

Страница 10: ...pen central heating system one of possible way how to connect the boiler to the system is shown on Scheme 1 In case of Bio Tec boilers the boiler pump obligatory has to be connected to the boiler cont...

Страница 11: ...e fuel the main switch of the boiler has to be turned on When the firing proces is over we can turn off the main switch but first it is necessary after the indication FUEL is turned on to wait that th...

Страница 12: ...s are for ignition of the boiler from cold state without glow These measures should be implemented always when we don t have or don t have enough glow and when we will load the wood Technical manual B...

Страница 13: ...ty in the system situated enough over the level of the highest radiator in the system and insulated if it is mounted outside of heated space if the mobile elements of the boiler are properly positione...

Страница 14: ...exchanger 1 outer thread1 2 the arrow shows the direction fix the tube connected to the sewage outlet at the connecting point 3 outer thread1 2 Boiler regulation By pressing two buttons simultaneously...

Страница 15: ...function to turn on off the regulator LED display shows the measured temperatures their ordinary number number or parameter value as well as the regulator functioning mode signal Indication START LED...

Страница 16: ...possible to restart the procedure of the filling the combustion chamber First is need to push START button indication LED 3 is flashing see Point 7 0 open te upper boiler door and fill upper combustio...

Отзывы: