9 - ACCESSORIES
Setting ranges for auxiliary high-flow hydraulic circuit
The maximum flow rate of the auxiliary high-flow hydraulic circuit can be set by monitor. The setting ranges are related
to the circuit type installed on the machine.
If single-acting circuit is installed, the maximum flow rate can be selected within the steps in the left column of the
table below.
If multifunction circuit is installed, the setting ranges are related to the circuit mode. In the Single-acting mode, the
maximum flow rate can be selected within the steps in the left column of the table below. In the Double-acting mode,
the maximum flow rate can be selected within the steps either in the left column or in the right column of the table
below.
NOTE:
all the values for maximum flow rate are related to the SP work mode. If the auxiliary high-flow hydraulic circuit
is used with a different work mode the actual flow will be lower.
1 pump flow
2 pumps flow
35 L/min
(
9.25 US gpm
)
164 L/min
(
43.32 US gpm
)
39 L/min
(
10.30 US gpm
)
168 L/min
(
44.38 US gpm
)
53 L/min
(
14.00 US gpm
)
182 L/min
(
48.08 US gpm
)
64 L/min
(
16.91 US gpm
)
193 L/min
(
50.99 US gpm
)
75 L/min
(
19.81 US gpm
)
204 L/min
(
53.89 US gpm
)
87 L/min
(
22.98 US gpm
)
216 L/min
(
57.06 US gpm
)
100 L/min
(
26.42 US gpm
)
229 L/min
(
60.50 US gpm
)
111 L/min
(
29.32 US gpm
)
240 L/min
(
63.40 US gpm
)
119 L/min
(
31.44 US gpm
)
248 L/min
(
65.51 US gpm
)
129 L/min
(
34.08 US gpm
)
258 L/min
(
68.16 US gpm
)
NOTE:
Five flow rate values can be set and stored for usage of single-acting hydraulic attachments. Five flow rate
values can be set and stored for usage of double-acting hydraulic attachments.
For the Single-acting circuit the working pressure shall be set manually by the port relief valve on the relevant section
of the control valve.
For the Multi-function circuit the working pressure shall be set manually by the relief valve located behind the boom
foot.
9-7
Содержание CX130C
Страница 16: ...1 GENERAL INFORMATION 1 10...
Страница 34: ...2 SAFETY INFORMATION SMIL20CEX1386HA 2 2 18...
Страница 75: ...3 CONTROLS AND INSTRUMENTS Display SMIL18CEX0554FB 2 SMIL18CEX0534FB 3 3 29...
Страница 112: ...3 CONTROLS AND INSTRUMENTS 3 66...
Страница 134: ...4 OPERATING INSTRUCTIONS 4 22...
Страница 150: ...5 TRANSPORT OPERATIONS 5 16...
Страница 199: ...6 MAINTENANCE Bucket cylinder bottom pin one grease fitting SMIL18CEX0523AA 7 6 49...
Страница 231: ...6 MAINTENANCE 8 Check that the tooth is securely fastened CA1C6271 3 6 81...
Страница 240: ...6 MAINTENANCE 6 90...
Страница 251: ...8 SPECIFICATIONS Working ranges SMIL20CEX1394HA 4 8 9...
Страница 254: ...8 SPECIFICATIONS 8 12...
Страница 278: ...9 ACCESSORIES 9 24...