6 - MAINTENANCE
Engine coolant
OAT E
XTENDED
L
IFE
C
OOLANT
/A
NTIFREEZE
is the reference genuine product for machine service.
NOTICE:
Never add Supplemental Coolant Additives (SCA) when using
OAT E
XTENDED
L
IFE
C
OOLANT
/A
NTIFREEZE
.
OAT E
XTENDED
L
IFE
C
OOLANT
/A
NTIFREEZE
has to be used if refilling of the cooling system is needed. Refer to the
dedicated procedure and recommendations described in Chapter 6.
OAT E
XTENDED
L
IFE
C
OOLANT
/A
NTIFREEZE
shall be used for the replacement of engine coolant according to the main-
tenance program of the machine. The replacement shall also be tackled in case of repair or replacement of compo-
nents of the cooling system. Refer to the dedicated procedure described in Chapter 6.
The engine cooling system shall always be refilled with coolant solution made by mixture of antifreeze and distilled
(deionized) water.
NOTICE:
Never refill the cooling system with only antifreeze. Never refill the cooling system with only water.
Using
OAT E
XTENDED
L
IFE
C
OOLANT
/A
NTIFREEZE
, a 50/50 mixture of antifreeze and distilled (deionized) water grants
proper performance of the engine cooling system in the above mentioned operating temperature range of the ma-
chine.
OAT E
XTENDED
L
IFE
C
OOLANT
/A
NTIFREEZE
is available as:
• 50/50 PREMIXED coolant solution ready for usage.
• CONCENTRATE antifreeze to be mixed 50/50 with distilled (deionized) water.
NOTICE:
If operating in extreme winter climate, a coolant solution made by 60/40 antifreeze/distilled (deionized) water
mixture shall be used in order to grant proper performance of the engine cooling system.
NOTICE:
Never use coolant solution with more than
60%
of antifreeze. This affects the cooling capacity of the mixture.
When the coolant solution is prepared starting from the CONCENTRATE product, the antifreeze concentration in the
mixture of antifreeze and distilled (deionized) water can be determined with a refractometer designed to measure
ethylene glycol content.
If distilled (deionized) water is not available, use water for dilution with the following properties:
Property
Maximum limit
Total Solids
340 ppm
Total Hardness
170 ppm
Chloride (Cl)
40 ppm
Sulfate (SO4)
100 ppm
Acidity pH
5.5 to 9.0
NOTICE:
Never use hard water, sea water and softened sea water that has been conditioned with salt. The minerals
and salts present in potable water can cause corrosion and deposits resulting in shortened engine life.
6-5
Содержание CX130C
Страница 16: ...1 GENERAL INFORMATION 1 10...
Страница 34: ...2 SAFETY INFORMATION SMIL20CEX1386HA 2 2 18...
Страница 75: ...3 CONTROLS AND INSTRUMENTS Display SMIL18CEX0554FB 2 SMIL18CEX0534FB 3 3 29...
Страница 112: ...3 CONTROLS AND INSTRUMENTS 3 66...
Страница 134: ...4 OPERATING INSTRUCTIONS 4 22...
Страница 150: ...5 TRANSPORT OPERATIONS 5 16...
Страница 199: ...6 MAINTENANCE Bucket cylinder bottom pin one grease fitting SMIL18CEX0523AA 7 6 49...
Страница 231: ...6 MAINTENANCE 8 Check that the tooth is securely fastened CA1C6271 3 6 81...
Страница 240: ...6 MAINTENANCE 6 90...
Страница 251: ...8 SPECIFICATIONS Working ranges SMIL20CEX1394HA 4 8 9...
Страница 254: ...8 SPECIFICATIONS 8 12...
Страница 278: ...9 ACCESSORIES 9 24...