7 Calibration the Scale
23
NUMERIC
< GRAVITY CONSTANTS >
At Calibration Place : 9.7994
At Using Place : [9.8024]
ZERO:
The Zero value is the current Zero value for the scale. It should be +10% from the calibrated
zero; however, if you change and save this value, it becomes the calibrated zero value.
While the cursor is on the Zero field, you can change this value but, you must press the ENTER
key twice for it to take effect. Lowering the value will lower the weight; increasing the value
will increase the weight. While the cursor is on the Zero field, can also press the TEST key to
bring the weight to 0.000. This also has the effect of changing the Zero value.
If you wish to save your changes, press the SAVE key at any time or the ENTER key while the
cursor is on the last field of the screen. If you wish to undo your changes, press the ESC key at anytime.
Once you leave this screen, the display will return to the previous screen (Calibration Menu.)
NOTE: Any changes made here will affect the NTEP Audit Trail counters (CAL counter only.)
7.4 Gravity Constant
Once at the Main menu
screen, press the 3 key. The
Gravity Constants screen will
appear:
If the Calibration Place &
the Using Place values are the
same, it means that the scale was
calibrated at that constant’s corresponding location(s) and thus no compensation takes place. If these
are different, this implies that the scale was calibrated at some other location than the Using Place
value. In this case compensation takes place.
The purpose of this function is to allow you to calibrate the scale in one location, say New York,
and then ship it to another location, say Panama, where you change the Using Place value from 9.8024
to 9.7814. This will compensate for the difference in gravity at the 2 locations and so you need not
recalibrate the scale. Press ENTER or SAVE to save changes or ESC to quit without changing.
Use the following table to determine the proper G-Constant for
your area.
Country
City
G-Constant
Country
City
G-Constant
Argentina
Buenos Aires
9.7979
Mexico
Mexico City
9.7799
Australia
Sydney
9.7979
Morocco
Rabat
9.7964
Austria
Vienna
9.8099
Netherlands
Amsterdam
9.8129
Belgium
Brussels
9.8114
New Zealand
Wellington
9.8039
Belize
Manamah
9.7904
Norway
Oslo
9.8189
Bolivia
La Paz
9.7844
Panama
Panama City
9.7814
Brazil
Brasilia
9.7889
Peru
Lima
9.7829
Montreal
9.8069
Philippines
Manila
9.7844
Ottawa
9.8069
Poland
Swider
9.8159
Toronto
9.8054
Portugal
Lisbon
9.8009
Canada
Vancouver
9.8099
Rumania
Bucharest
9.8054
Check Republic
Prague
9.8114
Saudi Arabia
Riyad
9.7904
Chile
Santiago
9.7979
Scotland
Stockholm
9.8189
China
Hong Kong
9.8099
Singapore
Singapore
9.7814
Colombia
Bogota
9.7799
South Africa
Johannesburg
9.7919
Costa Rica
San Jose
9.7829
Spain
Madrid
9.8024
Cypress
Nicosia
9.7979
Switzerland
Bern
9.8084
Содержание LP-2G
Страница 2: ......
Страница 8: ......
Страница 11: ...1 General 3 Note Specifications are subject to change without notice ...
Страница 46: ...11 Network Options 38 11 Network Options Refer to Network manual ...
Страница 66: ...16 Troubleshooting 58 16 2 Versioning Changes ...
Страница 69: ...17 Schematic Diagrams 61 17 3 Main PCB ...
Страница 70: ...17 Schematic Diagrams 62 17 4 Ethernet Memory Expansion PCB ...
Страница 71: ...17 Schematic Diagrams 63 17 5 Power Supply PCB ...
Страница 72: ...18 Exploded Views 64 18 Exploded Views 18 1 Scale ...
Страница 73: ...18 Exploded Views 65 18 2 Printer Assembly ...
Страница 74: ......
Страница 89: ...Appendix C 85 ...
Страница 90: ...Appendix C 86 ...
Страница 91: ...Appendix C 87 ...
Страница 92: ...Appendix C 88 ...
Страница 93: ...Appendix C 89 ...
Страница 94: ...Appendix C 90 ...
Страница 95: ...Appendix C 91 ...
Страница 96: ...Appendix C 92 ...
Страница 97: ...Appendix C 93 ...
Страница 98: ...Appendix C 94 ...
Страница 99: ...Appendix C 95 ...
Страница 100: ...Appendix C 96 ...
Страница 101: ...Appendix C 97 ...
Страница 102: ...Appendix C 98 ...
Страница 103: ...Appendix C 99 ...
Страница 104: ...Appendix C 100 ...