226
TESTACTC (cont)
Humidifier Act.Ctrl.Ang.
HUMDCANG
ERV Exh 2 Calibrate Cmd
No/Yes
MPB6_CAL
ERV Exh 2 Act Ctl Angle
ERV6CANG
TESTCOOL
Econ 1 Out Act.Cmd.Pos.
%
ECONCOOL
Static Pressure Setpoint
in H2O
SPSPCTST
Requested Cool Stage
CLST_TST
Compressor A1 Relay
Off/On
CMPA1TST
Minimum Load Valve Relay
Off/On
MLV_TST
Compressor A1 Capacity
%
A1CAPTST
Two Circuit Start A1,B1
Off/On
CMPABTST
Compressor A2 Relay
Off/On
CMPA2TST
Compressor A3 Relay
Off/On
CMPA3TST
Compressor A4 Relay
Off/On
CMPA4TST
Compressor B1 Relay
Off/On
CMPB1TST
Compressor B2 Relay
Off/On
CMPB2TST
Compressor B3 Relay
Off/On
CMPB3TST
Compressor B4 Relay
Off/On
CMPB4TST
HumidiMizer 3-way Valve
Off/On
RHVC_TST
Condenser EXV Position
%
CEXVCTST
Bypass EXV Position
%
BEXVCTST
TESTEXVS
Circuit A EXV 1 Position
%
A_X1_TST
Circuit A EXV 2 Position
%
A_X2_TST
Circuit B EXV 1 Position
%
B_X1_TST
Circuit B EXV 2 Position
%
B_X2_TST
Cir A EXV 1 Calibrate
Off/On
A_X1_CAL
Cir A EXV 2 Calibrate
Off/On
A_X2_CAL
Cir B EXV 1 Calibrate
Off/On
B_X1_CAL
Cir B EXV 2 Calibrate
Off/On
B_X2_CAL
TESTHEAT
Requested Heat Stage
HTST_TST
Heat Relay 1
Off/On
HS1_TST
Modulating Heat Capacity
%
MGAS_TST
Heat Relay 2
Off/On
HS2_TST
Relay 3 W1 Gas Valve 2
Off/On
HS3_TST
Relay 4 W2 Gas Valve 2
Off/On
HS4_TST
Relay 5 W1 Gas Valve 3
Off/On
HS5_TST
Relay 6 W2 Gas Valve 3
Off/On
HS6_TST
Relay 7 W1 Gas Valve 4
Off/On
HS7_TST
Relay 8 W2 Gas Valve 4
Off/On
HS8_TST
Relay 9 W1 Gas Valve 5
Off/On
HS9_TST
Relay 10 W2 Gas Valve 5
Off/On
HS10_TST
Heat Interlock Relay
Off/On
HIR_TST
Ht.Coil Command Position
%
HTCLHEAT
TESTHMZR
HumidiMizer 3-way Valve
Off/On
RHVH_TST
Condenser EXV Position
%
CEXVHTST
Bypass EXV Position
%
BEXVHTST
Condenser EXV calibrate
Off/On
CEXV_CAL
Bypass EXV calibrate
Off/On
BEXV_CAL
TESTINDP
Humidifier Relay
Off/On
HUMR_TST
Remote Alarm/Aux Relay
Off/On
ALRM_TST
OAU 2-Position Damper
Close/Open
S_OADMPR
OAU Wheel Test
%
S_WHEEL
OAU OA Fan Speed Test
%
S_OAFAN
OAU PE Fan Speed Test
%
S_EXFAN
OAU Tempring Heater Test
%
S_OAHEAT
VERSIONS
MBB CESR131461-
5-char ASCII
MBB_SW
RXB CESR131465-
5-char ASCII
RXB_SW
EXB CESR131465-
5-char ASCII
EXB_SW
CXB CESR131173-
5-char ASCII
CXB_SW
SCB CESR131226-
5-char ASCII
SCB_SW
CEM CESR131174-
5-char ASCII
CEM_SW
EXV CESR131172-
5-char ASCII
EXV_SW
APPENDIX B
—
CCN TABLES (CONT)
MAINTENANCE DISPLAY TABLES (cont)
TABLE
DISPLAY NAME
RANGE
UNITS
POINT NAME
WRITE STATUS
Содержание WeatherExpert 48N2
Страница 135: ...135 Fig 18 48 50N Typical Power Schematic Nominal 075 Ton Unit Shown ...
Страница 136: ...136 Fig 19 48 50N Typical Power Schematic Nominal Ton 90 150 Units Shown ...
Страница 137: ...137 Fig 20 48 50N Main Base Board Input Output Connections ...
Страница 138: ...138 Fig 21 48 50N RXB EXB CEM Input Output Connections a48 9307 ...
Страница 139: ...139 Fig 22 48 50N EXV SCB Input Output Connections a48 9308 ...
Страница 140: ...140 Fig 23 48N Typical Modulating Gas Heat Unit Control Wiring ...
Страница 141: ...141 Fig 24 50N Typical Electric Heat Unit Control Wiring ...
Страница 144: ...144 Fig 27 48N Typical Gas Heat Section Wiring Nominal Ton 120 to 150 Units ...
Страница 145: ...145 Fig 28 48 50N Typical Power Component Control Wiring 460 v ...
Страница 146: ...146 Fig 29 48 50N Component Control Wiring 575 v Nominal Ton 075 to 150 Units ...
Страница 147: ...147 Fig 30 48 50N Component Arrangement Power Box ...
Страница 148: ...148 Fig 31 48 50N Component Arrangement Control Box ...
Страница 168: ...168 Fig 47 Sensor and Ignition Position Fig 48 Combustion Blower Details SENSOR DETAILS IGNITION DETAILS ...
Страница 240: ...240 APPENDIX D VFD INFORMATION CONT Fig G VFD Bypass Wiring Diagram WHEN USED ...