SECTION 9
MICROPROCESSOR
9.1 CONTROLLED ATMOSPHERE CONTROLLER MODULE
3
3
5
6
7
1
2
3
3
3
4
1. Mounting Screw
2. CA Controller Module
3. Connectors
4. Test Points
5. Fuses
6. Control Circuit Power Connection
(Location: In back of connector)
7. Software Programming Port
Figure 63. Controlled Atmosphere Controller Module
9.1.1 Brief Description
WARNING
Do not attempt to service the CA Controller
module. Breaking the warranty seal will
void the warranty.
CAUTION
Remove all Controller modules and unplug
all wire harness connectors before per-
forming any arc welding on any part of the
container.
Do not remove wire harnesses from mod-
ules unless you are grounded to the unit
frame with a static safe wrist strap.
The Carrier Transicold CA module (identical to the ML2i
Temperature Controller used in the refrigeration system
with the exception of the software) is acustom-designed
microprocessor which incorporates electronic logic to:
a. Wait for proper refrigeration system conditions before
enabling start-up of the CA.
b. Control oxygen and carbon dioxide levels within a re-
frigeration container, and monitor the percentage lev-
el of nitrogen being generated.
c. Control The addition of carbon dioxide from an inde-
pendent source.
d. Provide dual independent readouts of set points and
concentration levels for oxygen and carbon dioxide.
e. Provide digital readout and ability to select data. Re-
fer to Table 22, page 102 for CA Controller Function
Codes. For CA Controller alarm digital display identi-
fication refer to Table 24, page 105.
f. Provide a pre-trip step-by-step checkout of CA sys-
tem performance, proper component operation,
proper electronic control operation, proper heater op-
eration and automatic sensor calibration.
g. Provide the ability to select function codes and
change selectable function codes, configuration vari-
ables and set points. Refer to section9.1.4, page102.
h. Provide memory reprogramability and configuration
through a memory card. The memory card automati-
cally downloads new software to the CA Controller
when inserted, and controls output to the display of
programming status information. (See section
12.14.1, page 133)
Содержание 69NT40-489-100 Series
Страница 2: ......
Страница 4: ......
Страница 14: ...Safety 10 T 305...
Страница 28: ...4 T 305...
Страница 40: ...16 T 305...
Страница 50: ...26 T 305 Figure 12 Standard Configuration Report...
Страница 112: ...88 T 305...
Страница 163: ...139 T 305 CFS KA6 CFA1 QC1 FDH HST RRS SINGLE SENSOR ONLY Figure 88 Wiring Diagram Sheet 2 of 2...
Страница 164: ...140 T 305...
Страница 167: ...143 T 305 Based on drawings 62 10526 Rev and 62 10736 Rev Figure 90 Electrical Schematic CA...
Страница 168: ...144 T 305 ALTERNATE CONFIGURATION Figure 91 Electrical Wiring Diagram Controlled Atmosphere Sheet 1 of 2...
Страница 169: ...145 T 305 F Figure 88 E Figure 88 Figure 91 Electrical Wiring Diagram Controlled Atmosphere Sheet 2 of 2...
Страница 172: ...148 T 305 Figure 93 Electrical Wiring Diagram Sheet 1 of 2 Units not modified to include the N2 Purity Solenoid Valve...
Страница 174: ...150 T 305...