81
T-305
6.25 COMMUNICATIONS INTERFACE MODULE
INSTALLATION
Communications
interface Module
CB1
Figure 53. Communications Interface
Installation
Units with communication interface module provision
have the required wiring installed. The provision wiring
kit (part number 76--00685--00), includes three
pre--addressed wires installed between the circuit
breaker and communication interface module locations.
These wires are to be connected to the module and
circuit breaker to allow the module to communicate over
the power system. To install the module, do the
following:
WARNING
THE UNIT POWER PLUG MUST BE DIS-
CONNECTED TO REMOVE POWER FROM
CIRCUIT BREAKER CB1
a.. CB1 is connected to the power system, see wiring
schematic. Ensure that the unit power is off AND
that the unit power plug is disconnected.
b.. Open control box, see and remove low voltage
shield. Open high voltage shield.
c.. Remove the circuit breaker panel, with circuit
breaker, from the control box.
d.. Locate, wires CB21/CIA3, CB22/CIA5 and
CB23/CIA7 that have been tied back in the wire
harness. Remove the protective heat shrink from
the ends of the wires.
e.. Attach the three wires as addressed to the LOAD
side of the circuit breaker.
f.. Refit the circuit breaker panel.
g. Fit the new RMU into the unit.
h. Remove plugs CIA, CIB and CID from the wiring
harness and attach to the module.
.i. Replace the low voltage shield.
Table 16. Recommended Bolt Torque Values
BOLT DIA. THREADS
TORQUE
MKG
FREE SPINNING
#4
#6
#8
#10
1/4
5/16
3/8
7/16
1/2
9/16
5/8
3/4
40
32
32
24
20
18
16
14
13
12
11
10
5.2 in-lbs
9.6 in-lbs
20 in-lbs
23 in-lbs
75 in-lbs
11 ft-lbs
20 ft-lbs
31 ft-lbs
43 ft-lbs
57 ft-lbs
92 ft-lbs
124 ft-lbs
0.05
0.11
0.23
0.26
0.86
1.52
2.76
4.28
5.94
7.88
12.72
17.14
NONFREE SPINNING (LOCKNUTS ETC.)
1/4
5/16
3/8
7/16
1/2
9/16
5/8
3/4
20
18
16
14
13
12
11
10
82.5 in-lbs
145.2 in-lbs
22.0 ft-lbs
34.1 ft-lbs
47.3 ft-lbs
62.7 ft-lbs
101.2 ft-lbs
136.4 ft-lbs
0.95
1.67
3.04
4.71
6.54
8.67
13.99
18.86
6.26 POWER FACTOR CORRECTOR
CAPACITORS (PFC)
The power factor corrector capacitors are of the
permanent-split capacitor type. There are a total of
three capacitors with discharge resistors enclosed in a
single case.
a. When to check for a defective capacitor
The capacitors assist in correcting current draw by the
compressor. If one or more of the capacitors is faulty,
there will be an imbalance in current. In addition, the
power consumption of the unit will increase.
b. Removing the capacitor
WARNING
Make sure power to the unit is OFF and
power plug disconnected before removing
capacitor(s).
WARNING
Before removing the capacitors the
terminals must be checked for voltage with
a multimeter. The discharge resistors
installed on the unit (capacitors) should
bring the voltage to a safe level in a minute.
However, there may be a broken resistor
that retains voltage for a longer period, it is
highly recommended to wait 15 minutes
and to check for voltage.
Содержание 69NT40-489-100 Series
Страница 2: ......
Страница 4: ......
Страница 14: ...Safety 10 T 305...
Страница 28: ...4 T 305...
Страница 40: ...16 T 305...
Страница 50: ...26 T 305 Figure 12 Standard Configuration Report...
Страница 112: ...88 T 305...
Страница 163: ...139 T 305 CFS KA6 CFA1 QC1 FDH HST RRS SINGLE SENSOR ONLY Figure 88 Wiring Diagram Sheet 2 of 2...
Страница 164: ...140 T 305...
Страница 167: ...143 T 305 Based on drawings 62 10526 Rev and 62 10736 Rev Figure 90 Electrical Schematic CA...
Страница 168: ...144 T 305 ALTERNATE CONFIGURATION Figure 91 Electrical Wiring Diagram Controlled Atmosphere Sheet 1 of 2...
Страница 169: ...145 T 305 F Figure 88 E Figure 88 Figure 91 Electrical Wiring Diagram Controlled Atmosphere Sheet 2 of 2...
Страница 172: ...148 T 305 Figure 93 Electrical Wiring Diagram Sheet 1 of 2 Units not modified to include the N2 Purity Solenoid Valve...
Страница 174: ...150 T 305...