89
T-305
SECTION 8
DESCRIPTION
8.1 GENERAL DESCRIPTION
8.1.1 CA Equipment Location -- front Section
Many of the Controlled Atmosphere (CA) components
are accessible from the front of the unit. These items,
see Figure 56, include the intake air filter and pressure
relief (breather) valve mounted in the right upper access
panel, three access ports, flow meter, and the controlled
atmosphere control box.
8.1.2 Calibration, Gas Charge and Pressurization/
Gauge Ports
The
calibration
gas,
CO
2
charge
and
pressurization/gauge ports are all located on the front of
the unit, see Figure 56. A second CO
2
charge port is
located in the evaporator section, see Figure 57, page
90.
Functions of the various ports are:
S
Pressurization/gauge ports are used to leak
check the container by pressurizing with one
port and attaching a pressure gauge onto the
other port and monitoring for leakage.
S
A calibration gas port is used with the
Controlled Atmosphere (CA) Controller and a
calibration gas tank to calibrate the oxygen
sensor and to check the carbon dioxide
sensor.
S
Carbon dioxide charge ports are used for
applications requiring increased concentration
levels of carbon dioxide.
5
1
2
3
4
6
7
8
9
2
2
1. Air Intake Filter, Pressure Relief (Breather)
Valve & Access Panel
2. CA Warning Labels
3. Refrigeration Unit Control Box
4. Pressurization/Gauge Ports (For Container Leak
Check)
5. Flow Meter (gas calibration)
6. Gas Calibration Port (Used to calibrate the O
2
sensor and to check the CO
2
sensor)
7. Front Carbon Dioxide Gas Charge Port
(Used to attach a CO
2
bottle)
8. Controlled Atmosphere Control Box
9. Fresh Air Makeup Vent & Access Panel
Figure 56. Controlled Atmosphere Components -- Front Section
Содержание 69NT40-489-100 Series
Страница 2: ......
Страница 4: ......
Страница 14: ...Safety 10 T 305...
Страница 28: ...4 T 305...
Страница 40: ...16 T 305...
Страница 50: ...26 T 305 Figure 12 Standard Configuration Report...
Страница 112: ...88 T 305...
Страница 163: ...139 T 305 CFS KA6 CFA1 QC1 FDH HST RRS SINGLE SENSOR ONLY Figure 88 Wiring Diagram Sheet 2 of 2...
Страница 164: ...140 T 305...
Страница 167: ...143 T 305 Based on drawings 62 10526 Rev and 62 10736 Rev Figure 90 Electrical Schematic CA...
Страница 168: ...144 T 305 ALTERNATE CONFIGURATION Figure 91 Electrical Wiring Diagram Controlled Atmosphere Sheet 1 of 2...
Страница 169: ...145 T 305 F Figure 88 E Figure 88 Figure 91 Electrical Wiring Diagram Controlled Atmosphere Sheet 2 of 2...
Страница 172: ...148 T 305 Figure 93 Electrical Wiring Diagram Sheet 1 of 2 Units not modified to include the N2 Purity Solenoid Valve...
Страница 174: ...150 T 305...