Operation section

Select a desired operation by pushing each button.

FILTER RESET

LOUVER

FAN

TEMP.

MODE

MONITOR/SET ALL/ZONE

ZONE

UNIT

ON CENTER/LOCKED

CHECK

ZONE SET/ENTER SELECT

OFF

TIMER ON

Sets and enters the zone.

ZONE SET/ENTER

Selects “MONITOR” or “SET” 
mode.

MONITOR/SET button

Selects Last-push priority/Center/Locked.

Last-push priority/Center/Locked button

Selects that start/stop/every 
set up operations are 
performed for all units, zone, 
or individual unit.

ALL/ZONE/UNIT button

Discharge louver 
automatically operates while 
the air conditioner is under 
operation.

LOUVER button

Used in servicing. Do not 
operate this button in normal 
time.
For symptom check, the 
Code No. can be observed. 
(For details, see p.18.)

CHECK button

Resets (Erases) “FILTER” 
indication.

FILTER RESET button

Selects the desired operation 
mode.

MODE button

Adjusts the room temperature.
Adjust the temperature to the 
desired set temperature by 
pushing       . (18 to 29˚C)

TEMP. button

Selects the desired fan mode. 

FAN button

Selects unit No. to be 
entered in the zone.

SELECT button

Validates the weekly timer or 
timer on the market.

TIMER ON button

Indicates the desired zone No.
The desired zone No. is 
indicated by pushing        .

ZONE No. button

Indicates the desired unit No.
The desired unit No. is 
indicated by pushing        .

UNIT No. button

Starts/Stops the air conditioner.

ON/OFF button

Содержание 40RC003603

Страница 1: ...d Functions 3 Names and Operation of Each Part 4 Entering to Zone 7 Cancel of Zone Entering 8 Operation 9 Start Stop Operation for ALL ZONE 13 Timer Operation 14 Set Up Method of Operation Mode 15 Adj...

Страница 2: ...d or by specialist Never insert metals such as a pin or wire into a hole or clearance It may cause a fire or electric shock Never handle the switches with wet hands It may cause an electric shock Do n...

Страница 3: ...ely controlled from the separated positions Remote controller management at indoor unit side Three functions last push priority mode center mode or operation lock mode can be selected Filter sign FILT...

Страница 4: ...gle remote controller Two remote controllers or Single remote controller Two remote controllers Max 16 units Max 16 units System 1 Central remote controller System 2 System 3 System 4 System 5 System...

Страница 5: ...e No ZONE No indication Indicates that start stop every set up operations are performed for all units zone or individual unit ALL ZONE UNIT indication Indicates that the air conditioner of which unit...

Страница 6: ...ion LOUVER button Used in servicing Do not operate this button in normal time For symptom check the Code No can be observed For details see p 18 CHECK button Resets Erases FILTER indication FILTER RES...

Страница 7: ...T button the flashing Unit No in the operation monitor indication part goes on Repeat steps 3 and 4 and select Unit No 3 4 and 5 5 When ZONE SET ENTER button is pushed the contents are entered Unit No...

Страница 8: ...n the corresponding zone go on 1 is indicated at shipment from the factory Unit No 1 is set to Zone No 1 3 Pushing UNIT button matches Unit No to be canceled The matched No is indicated in Unit No ind...

Страница 9: ...AN AUTO TEMP C LOUVER LOUVER FAN TEMP MODE MONITOR SET ALL ZONE ZONE UNIT ON CENTER LOCKED CHECK ZONESET ENTER SELECT OFF TIMERON FILTERRESET 49 64 33 48 17 32 1 SET CENTER ON MODE COOL ON UNIT 2 3 4...

Страница 10: ...T No indication Last push priority CENTER LOCKED 3 Selection of ZONE No Push ZONE button to match to ZONE No to be set Unit No entered in the indicated zone is indi cated in the Operation monitor indi...

Страница 11: ...OCKED Push CENTER LOCKED button to match indication to No indication Last push prior ity CENTER or LOCKED NOTE Every pushing the button indication changes in the following order 6 SET Match MODE FAN T...

Страница 12: ...button OFF indication goes on END Selection of MONITOR SET Push MONITOR SET button again to match to MONITOR SET indication goes off and MONITOR indication goes on Indication returns automatically to...

Страница 13: ...L ZONE button to match to ZONE ZONE ON and OFF indications flash 3 Selection of ZONE No Push ZONE button to match to the ZONE No to be started or stopped All the entered UNIT Nos of in the Zone are in...

Страница 14: ...lection of ALL ZONE UNIT Push ALL ZONE button to select ALL ZONE or UNIT for the indoor units to be set NOTE Every pushing the button indication changes in the following order ALL ZONE UNIT When ALL i...

Страница 15: ...ion changes in the following order Indication differs according to Model type 5 Selection of FAN Push FAN button to select the Fan mode NOTE Every pushing the button indication changes in the followin...

Страница 16: ...utton LOUVER indication goes off Push MONITOR SET button again to match MONITOR Then the setting completes The discharge louver stops soon REQUIREMENT Do not move the discharge louver directly with ha...

Страница 17: ...t indicated If the power of the air conditioner is turned off the extended operation time is held Fire alarm signal Connecting a fire alarm signal of the fire alarm panel all the connected units stop...

Страница 18: ...g status of trouble Check procedure Push CHECK button for 1 or 2 seconds CHECK indication appears The unit number is indicated and then the Check code number and alphabat is displayed in the TEMP indi...

Страница 19: ...onsumption Max 2W Use ambient temp Humidity 0 to 40 C up to 80 However no dewing Dimension 180 x 120 x 65 6 Width x Height x Depth Mass 420g External View Specifications and external view of this prod...

Отзывы: