background image

16

Adjustment of Air Direction

• For details, refer to the Owner’s Manual attached to the indoor unit.

To operate the discharge louver automatically

1

Selection of MONITOR/SET
Push “MONITOR/SET” button to match to “SET”.
If the operation stops,
push “ON” button. “ON” indication goes on.

2

Selection of LOUVER
Push “LOUVER” button. “LOUVER” indication
goes on.
Push “MONITOR/SET” button again to match to
“MONITOR”, and setting completes.

FILTER RESET

49

64

33

48

17

32

1

SET

ON

MODE

COOL

ON

UNIT

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

FAN

AUTO

TEMP.

LOUVER

LOUVER

FAN

TEMP.

MODE

MONITOR/SET ALL/ZONE

ZONE

UNIT

ON CENTER/LOCKED

CHECK

ZONE SET/ENTER SELECT

OFF

TIMER ON

2

1

˚C

To fix the discharge louver at a specific position

Push “MONITOR/SET” button to match to “SET” while the air conditioner operates (Louver operation), and push the
“LOUVER” button.

• “LOUVER” indication goes off.

Push “MONITOR/SET” button again to match “MONITOR”.  Then the setting completes.

• The discharge louver stops soon.

REQUIREMENT

Do not move the discharge louver directly with hands. It may cause a trouble.
Select the direction of the discharge louver by the Louver operation button on the remote controller.

When using an air conditioner of which discharge louver has no AUTO function

When using the central remote controller on an air condi-
tioner of which discharge louver has no AUTO function,
“LOUVER” and “MANUAL” indications go on by pushing the
Louver operation button, after a while they go off.

• In this time, fix the discharge louver to the desired position

for usage.

NOTIFICATION

• If cooling operation is performed with downward discharging of louver, dewing is caused on the cabinet or

surface of the louver resulted in falling of dewdrops.

• If heating operation is performed with horizontal discharging of louver, temperature unevenness may become

large in the room.

LOUVER

MANUAL

Содержание 40RC003603

Страница 1: ...d Functions 3 Names and Operation of Each Part 4 Entering to Zone 7 Cancel of Zone Entering 8 Operation 9 Start Stop Operation for ALL ZONE 13 Timer Operation 14 Set Up Method of Operation Mode 15 Adj...

Страница 2: ...d or by specialist Never insert metals such as a pin or wire into a hole or clearance It may cause a fire or electric shock Never handle the switches with wet hands It may cause an electric shock Do n...

Страница 3: ...ely controlled from the separated positions Remote controller management at indoor unit side Three functions last push priority mode center mode or operation lock mode can be selected Filter sign FILT...

Страница 4: ...gle remote controller Two remote controllers or Single remote controller Two remote controllers Max 16 units Max 16 units System 1 Central remote controller System 2 System 3 System 4 System 5 System...

Страница 5: ...e No ZONE No indication Indicates that start stop every set up operations are performed for all units zone or individual unit ALL ZONE UNIT indication Indicates that the air conditioner of which unit...

Страница 6: ...ion LOUVER button Used in servicing Do not operate this button in normal time For symptom check the Code No can be observed For details see p 18 CHECK button Resets Erases FILTER indication FILTER RES...

Страница 7: ...T button the flashing Unit No in the operation monitor indication part goes on Repeat steps 3 and 4 and select Unit No 3 4 and 5 5 When ZONE SET ENTER button is pushed the contents are entered Unit No...

Страница 8: ...n the corresponding zone go on 1 is indicated at shipment from the factory Unit No 1 is set to Zone No 1 3 Pushing UNIT button matches Unit No to be canceled The matched No is indicated in Unit No ind...

Страница 9: ...AN AUTO TEMP C LOUVER LOUVER FAN TEMP MODE MONITOR SET ALL ZONE ZONE UNIT ON CENTER LOCKED CHECK ZONESET ENTER SELECT OFF TIMERON FILTERRESET 49 64 33 48 17 32 1 SET CENTER ON MODE COOL ON UNIT 2 3 4...

Страница 10: ...T No indication Last push priority CENTER LOCKED 3 Selection of ZONE No Push ZONE button to match to ZONE No to be set Unit No entered in the indicated zone is indi cated in the Operation monitor indi...

Страница 11: ...OCKED Push CENTER LOCKED button to match indication to No indication Last push prior ity CENTER or LOCKED NOTE Every pushing the button indication changes in the following order 6 SET Match MODE FAN T...

Страница 12: ...button OFF indication goes on END Selection of MONITOR SET Push MONITOR SET button again to match to MONITOR SET indication goes off and MONITOR indication goes on Indication returns automatically to...

Страница 13: ...L ZONE button to match to ZONE ZONE ON and OFF indications flash 3 Selection of ZONE No Push ZONE button to match to the ZONE No to be started or stopped All the entered UNIT Nos of in the Zone are in...

Страница 14: ...lection of ALL ZONE UNIT Push ALL ZONE button to select ALL ZONE or UNIT for the indoor units to be set NOTE Every pushing the button indication changes in the following order ALL ZONE UNIT When ALL i...

Страница 15: ...ion changes in the following order Indication differs according to Model type 5 Selection of FAN Push FAN button to select the Fan mode NOTE Every pushing the button indication changes in the followin...

Страница 16: ...utton LOUVER indication goes off Push MONITOR SET button again to match MONITOR Then the setting completes The discharge louver stops soon REQUIREMENT Do not move the discharge louver directly with ha...

Страница 17: ...t indicated If the power of the air conditioner is turned off the extended operation time is held Fire alarm signal Connecting a fire alarm signal of the fire alarm panel all the connected units stop...

Страница 18: ...g status of trouble Check procedure Push CHECK button for 1 or 2 seconds CHECK indication appears The unit number is indicated and then the Check code number and alphabat is displayed in the TEMP indi...

Страница 19: ...onsumption Max 2W Use ambient temp Humidity 0 to 40 C up to 80 However no dewing Dimension 180 x 120 x 65 6 Width x Height x Depth Mass 420g External View Specifications and external view of this prod...