EN
www.carlisleft.com
77
-
3345 R1.1 (06/2022)
32 / 62
Be sure to store all removed parts in a safe place.
5. Disassembly instructions:
Unscrew the four screws (1) holding the upper connection
(2) housing to the lower connection housing (3). The
upper connection housing can be pulled off the lower.
Two O
-
rings (4) are used to seal the material channels
between the two parts and the two pins (5) help guide the
part when they are assembled.
If need be the plug (6) and push
-
in elbow coupling (7) can
be removed for easier access to the drainage channel.
The nipples (8) can be removed and exchanged should it
be needed.
2
3
5
4
Unless the pressure or temperature sensors are malfunctioning they
should NOT be removed from the lower connection housing. Removing or
cleaning either of the sensors may damage them and cause them to
malfunction.
CAUTION
!
6
7
8
1