EN
www.carlisleft.com
77
-
3345 R1.1 (06/2022)
31 / 62
Be sure to store all removed parts in a safe place.
5. Disassembly instructions:
Version without circulation and sensors:
Unscrew the four screws (1) and remove the
connector and plate (2), the cable bridge (3) to the
solenoids can be disconnected from the connector (4).
If need be the plug (5) and push
-
in elbow coupling
(6) can be removed for easier access to the drainage
channel.
Version with circulation and sensors:
Unscrew the four screws (7) holding the connector
plate (8) to the connection housing. Unplug all the
push and pull connectors (9) from the connector.
Be careful when removing the connector plate to
avoid damaging the cables and connectors for the
sensors.
1
7
3
2
6
5
To avoid damages to the sensor cables use
caution when removing the connector and
plate.
NOTE
8
9
4