Dynacode II Series
Installation and Initial Operation
08.16
Operating Manual
37
7.4 Adjustment of Pressure Power
Pressure power in dependence
of air pressure c53 / i53
(one pressure cylinder)
0
1
2
3
4
5
2
3
4
5
Air pressure in bar
P
re
s
s
u
re
i
n
k
g
Lift 1 mm
Lift 2 mm
Lift 3 mm
Pressure power in dependence
of air pressure c107 / i107
(two pressure cylinder)
0
1
2
3
4
5
6
7
8
2
3
4
5
Air pressure in bar
P
re
s
s
u
re
i
n
k
g
Lift 1 mm
Lift 2 mm
Lift 3 mm
Pressure power in dependence
of air pressure c128 / i128
(two pressure cylinders)
0
1
2
3
4
5
6
7
8
2
3
4
5
Air pressure in bar
P
re
s
s
u
re
i
n
k
g
Lift 1 mm
Lift 2 mm
Lift 3 mm
The pressure power of the printhead can be set with the pressure
regulator. The values are indicated in the following table:
NOTICE!
If the pressure power is set too low then the printhead has no
more contact to the counter-pressure plate. This damages the
printhead due to the missing heat dissipation during the
printout. In case of too low pressure an error message
appears. This error message is to protect the printhead for
overheating only and is not to use as print quality control (the
control suffers with too low pressure, too).
The
Lift
indicates the distance between printhead and counter-
pressure plate in idle mode of the device.
DC II 53
DC II 107
DC II 128
Recommended pressure power
40 N
40 N
40 N
Max. pressure power
45 N
45 N
45 N
As the mechanical wear and tear of the printhead increases with the
pressure power, the pressure power should be as low as possible.