7.3 Connection of Pneumatic Power Supply
The pneumatic power supply for the printhead mechanics has to be
made available a minimum continuous pressure of 4 - 6 bars in front
of the pressure regulator. The maximum pressure in front of the
pressure regulator is 7 bars and 4 bars after the pressure regulator.
NOTICE!
A pneumatic power supply of 4 bars is recommended.
The compressed-air has to be dry and oil free.
The supplied pressure regulator with manometer is to connect with a
pneumatic tube Ø 8 mm via a plugging bolting to the pneumatic power
supply. It is necessary to make a connection between the pressure
regulator and the print mechanics via a pneumatic tube Ø 8 mm.
Please observe the following notes:
Position pressure regulator as near as possible to the print
mechanics.
The pressure regulator is only to operate in the direction that is
indicated on its underside. The direction shows the way of the
streaming air.
It is not allowed to bend the pneumatic tubes.
Shortening of the pneumatic tubes has to be made with a clean
right-angled cut without squashing the tube. If necessary use
special tools (available in pneumatic requirements).
Please observe a possible short length of the 8 mm pneumatic
tubes.
Druckmechanik
Druckluftversorgung
Pneumatikschlauch
min. 4 bar, max. 7 bar
Druckregler mit Manometer
Print mechanics
Pneumatic power supply
Pneumatic tube 8x1
Pressure regulator with manometer
Figure 29