11
- Terra
N - Comune
2 - Apre
3 - Chiude
- Ground
N - Neutral
2 - Open
3 - Close
- Terre
N - Commun
2 - Ouvre
3 - Ferme
- Erdung
N - Gemeinsam
2 - Öffnen
3 - Schließen
- Aarding
N - Gemeensch.
2 - Openen
3 - Sluiten
C
TAL
21
20
19
18
17
16
15
14
13
12
11
5
6
7
8
9
10
TD
ANTENNA
TC TA
NC
TB
COMMON
FCA
FCC
COMMON
NO
NO
NO
NO
M2
CLOSING
COMMON
OPENING
C
M1
OPENING
COMMON
CLOSING
1
2
24V 12V
0
C
1
6
5
4
3
2
NO
NC
NC
C
NO
1
3
2
CLOSING
COMMON
OPENING
1
3
2
24V
12V
0
N
2
3
M1
N
2
3
M2
BRIDGE
1
2
C2
1
2
CLOSING M2
OPENING M2
CLOSING M1
OPENING M1
COMMON
TORQUE LIMIT
Max: 230
Vac
A:
195 Vac
B:
170 Vac
C:
145 Vac
MIN:
120 Vac
M
AX
A
B
C
M I N
COMMON
24V AC
ELS
12V ~
22
23
24
25
26
27
28
29
30
NC
NC
FTC_S
NC
FTC_I
NC
LS
LP
24V
N.
Live
LEGEND
TA:
OPENING BUTTON
TC:
CLOSING BUTTON
TB:
BLOCKING BUTTON (bridge if unused)
TD:
DYNAMIC BUTTON (open-close)
TAL:
LIMITED OPENING
FCC:
CLOSING TRAVEL LIMIT (bridge if unused)
FCA:
OPENING TRAVEL LIMIT (bridge if unused)
FTC_S: STOP PHOTOCELL (bridge if unused)
FTC_I: INVERTING PHOTOCELL(bridge if unused)
LP:
FLASHING WARNING LIGHTS (24Vac)
LS:
INDICATOR LAMP (24Vac)
ELS:
ELECTRIC LOCKING DEVICE (12Vac)
NO:
NORMALLY OPEN CONTACT
NC:
NORMALLY CLOSED CONTACT
C
NO
NC
3
FUSE
5A (230V)
10A (110V)
C1
TORQUE LIMITER
Max: 110
Vac
A:
100 Vac
B:
90 Vac
C:
80 Vac
MIN:
70 Vac
230V 50Hz
110V 60Hz
230V (EEC)
110V (USA)
12,5
µ
F (EU)
40
µ
F (USA)
EUROPE
USA
12,5
µ
F (EU)
40
µ
F (USA)
4
SEL
FTC RX
FTC TX
ELS
LP
UTILIZZARE PER IL COLLEGAMENTO ELETTRICO CAVO MULTIPOLARE FLESSIBILE 3 x 1 + T
USE FLEXIBLE MULTIWIRE CABLES FOR THE ELECTRICAL CONNECTION 3 x 1 + EARTH WIRE
POUR LE BRANCHEMENT ÉLECTRIQUE, UTILISER UN CÂBLE MULTIPOLAIRE FLEXIBLE 3 X 1 + T
ZUM ANSCHLUSS EIN MEHRPOLIGES FLEXIBLES ELEKTROKABEL 3 X 1 + T VERWENDEN.
GEBRUIK FLEXIBELE KABEL ,MINSTENS 3x1.5 + PE VOOR DE VERBINDING VAN DE MOTOREN
SCHEMA ELETTRICO IMPIANTO TIPO - STANDARD WIRING DIAGRAM - SCHÉMA ÉLECTRIQUE DE L'EXEMPLE D'INSTALLATION
ELEKTRISCHER SCHALTPLAN ANLAGENART - ELEKTRISCH AANSLUITSCHEMA MET CARDIN BESTURINGSKAST
PRG101LSO
21