SAFETY PRECAUTIONS
The following precautions should be observed when servicing.
1.
Since many parts in the unit have special safety-related characteristics, always use genuine CANON replacement parts.
Especially critical parts in the power circuit block should not be replaced with other makes.
Critical parts are marked with
!
in the schematic diagrams.
2.
When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or damaged
by the short circuit.
3.
After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly installed.
4.
After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
4-1 Leakage Current Cold Check
1) Unplug the AC cord and connect a jumper between the two prongs on the plug.
2) Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed metallic cabinet part
on the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to
the chassis, the reading should be between 1M
Ω
and 5.2M
Ω
. When the exposed metal does not have a return path to the
chassis, the reading must be
∞
.
4-2 Leakage Current Hot Check
1) Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2) Connect a 1.5K
Ω
10 watt resistor, paralleled by 0.15
µ
F capacitor, between each exposed metallic parts on the unit and a
good earth ground such as a water pipe, as shown in the figure below.
3) Use an AC voltmeter, with 1000
Ω
/volt or more sensitivity, to measure the potential across the resistor.
4) Check all exposed metallic parts of the cover (Cable connection, Handle bracket, metallic cabinet.
Screwheads, Metallic overlays, etc), and measure the voltage at each point.
5) Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6) The potential at any point should not exceed 0.75V RMS.
A leakage current tester (FLUKE MODEL : 8000A equivalent) may be used to make the hot checks.
Leakage current must not exceed 0.5 milliamp.
In case a measurement is outside of the limits specified, there is a possibility of a shock hazard, and corrective action must
be taken before returning the instrument to the customer.
Water pipe
(Earth Ground)
1.5K
Ω
0.15
µ
F
Test all
exposed
metal parts
Figure. 1 Leakage Current Hot Check
AC OUTLET
AC VOLTMETER
DEVICE
UNDER
TEST
Содержание PowerShot G3
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 35: ...1 29 3 2 6 dimensional Diagram 69 9 2 75 43 5 1 71 122 0 4 80 71 7 2 82 73 9 2 91 121 0 4 76 ...
Страница 60: ......
Страница 62: ......
Страница 132: ......
Страница 135: ...PowerShot G3 Pg2 INTERNAL PARTS SECTION 1 See Pg3 See Pg5 8 8 7 1 2 3 4 9 7 10 8 11 5 6 N S ...
Страница 139: ...PowerShot G3 Pg4 TOP COVER SECTION 17 15 16 1 3 7 2 4 5 6 8 15 9 10 11 12 13 14 ...
Страница 141: ...PowerShot G3 Pg5 EVF UNIT SECTION 1 10 2 5 3 7 12 11 12 4 6 8 13 9 a b a d c b d c ...
Страница 143: ...PowerShot G3 Pg6 BATTERY BOX UNIT SECTION 8 4 8 2 3 7 1 5 8 8 8 6 ...
Страница 145: ...PowerShot G3 Pg7 Fuse 2 1 DC DC CONVERTER PCB ASS Y ...
Страница 156: ......
Страница 169: ...C CANON INC 2002 01 NOVEMBER 2002 3 3 STJ PCB ASS Y STJ PCB ASS Y SOLDERING SIDE STJ PCB ASS Y COMPONENT SIDE ...
Страница 170: ...C CANON INC 2002 01 NOVEMBER 2002 3 4 HV MODULE UNIT ...
Страница 171: ...C CANON INC 2002 01 NOVEMBER 2002 3 5 TOP MODULE UNIT ...
Страница 172: ...C CANON INC 2002 01 NOVEMBER 2002 3 6 LCD PCB ASS Y ...
Страница 173: ...C CANON INC 2002 01 NOVEMBER 2002 3 7 OPTICAL FLX ...
Страница 174: ...C CANON INC 2002 01 NOVEMBER 2002 3 8 EF FLX ...
Страница 175: ...C CANON INC 2002 01 NOVEMBER 2002 3 9 R_EN FLX ...
Страница 178: ...PowerShot G3 Auto Focus Chart 1 ...
Страница 179: ...Dimensions 1 107 1mm 79 1mm Dimensions 1 ...
Страница 180: ...PowerShot G3 Auto Focus Chart 2 ...
Страница 181: ...Dimensions 2 278 46mm 207 66mm ...
Страница 182: ...PowerShot G3 Auto Focus Chart 1 ...
Страница 183: ...Dimensions 1 107 1mm 79 1mm Dimensions 1 ...
Страница 184: ...PowerShot G3 Auto Focus Chart 2 ...
Страница 185: ...Dimensions 2 278 46mm 207 66mm ...