/[x] : Upgrade (xxxxx)has been selected. Execute?
-(OK):0 / (CANCEL): Any other keys-
MNCON(STD) : 01.32 -> 01.33
MNCON(SAFE) : 01.32 -> 01.34
DCON : 01.02 -> 01.03 ACC4 : - RCON : - CCM : -
ACC1 : - ACC5 : - RCOND : 02.10>02.10 CCB : -
ACC2 : - ACC6 : - UICON_L : 02.30 -> 02.30 TSP : -
ACC3 : - ACC7 : - UICON : -
During the process, the download status is displayed on the Control Panel.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
FirmDownload 0% FirmBackup -%
StdCont -%
Dcon -% CCM -%
ACC1 -% CCB -%
ACC2 -% RCON -%
ACC3 -% TSP -%
Reboot
SafeCont -%
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Updating software... Do not turn OFF the main power.
Mise a jour du ligiciel... Ne mettez pas le peripherique hors tension.
Software wird aktualisiert...Schalten Sie das Gerat nicht AUS.
ソフトウェアの更新中です。電源を切らないでください。
Writing to the system area is started once download is completed. When writing to the DCON (ACC1, CCM or CCB if there
is an option) is completed, the machine is automatically restarted. After writing of SafeCont is completed, the machine is
automatically restarted again.
7. The main menu will appear. Press the Remove key at the lower-right corner of the Touch Panel, select [Remove
Memory Media], and remove the USB device.
8. Enter service mode to check the version of the system software.
● Controller-by-Controller Version Upgrade Procedure
Only a specific controller is upgraded.
1. Remove the network cable if any network cable is connected to the host machine.
2. Turn ON the main power of the host machine, and execute the following service mode to enter download mode.
• COPIER > Function > SYSTEM > DOWNLOAD
3. Press [1] and select the version of system software to be used on the screen for selecting version.
[ [ [ [ [ [ [ [ Select Version (USB) <v00.00> ] ] ] ] ] ] ] ] (v00.00)
-------------------------------------------------------
[1] : iAC0000_USBSet_0123-0000
[C] : Return to Root Menu
Do not turn OFF power without executing the shutdown sequence.
4. Select [5]: Select Update.
4. Firmware Management
81
Содержание imageRUNNER ADVANCE System V3.13
Страница 10: ...Authentication 2 Login Services 6 Management of the Authentication Method 11 Management of Users 17 ...
Страница 40: ...Firmware Management 4 Overview 36 Update Using Updater 47 Version Update Using Download Mode 70 ...
Страница 51: ...7 Restore the backed up setting values obtained in step 1 4 Firmware Management 46 ...
Страница 92: ...MEAP Application Management 6 About SMS 88 Settign Procedure 90 Maintenance 97 Troubleshooting 103 ...
Страница 120: ...5 Confirm that is displayed on the right side of the selected file and press 7 Backup Restoration 115 ...
Страница 146: ...Monitoring Function 8 E RDS 142 ...
Страница 155: ...APPENDICES Automatic Recovery Function 151 Special Startup 153 Backup List 159 Detail of Storage partition 175 ...
Страница 179: ...Not installed Flash PCB Backup List 174 ...