Functional cate-
gory
Sub category
Description
Transmission of
counters
Billing / Parts
E-RDS periodically sends billing/parts counter to Remote Monitoring Server.
Transmission of
event logs
Error/Alarm/Jam
Each time a service call, alarm, or jam occurs sends the error log to Remote Mon-
itoring Server.
Calibration log
Each time calibration is executed in the device, E-RDS sends the log to Remote
Monitoring Server.
Data transmission
ROM version / Device con-
figuration
E-RDS periodically sends the firmware information of the device to Remote Moni-
toring Server. E-RDS sends the device configuration information only when there is
any change in the configuration.
E-RDS debug log
Debug logs of E-RDS are stored in E-RDS, and they are sent to Remote Monitoring
Server only when they exceed a specific size.
Environment log
E-RDS periodically sends environment information (such as the temperature inside
the machine) to Remote Monitoring Server.
SMART information
E-RDS periodically sends SMART information of the storage to Remote Monitoring
Server.
Service Mode Menu
E-RDS sends some of the data of Service Mode Menu when it detects a specific
alarm or service call log error or when it detects a change in the settings of Service
Mode Menu.
Sublog transmission
E-RDS sends data, such as sublog or DCON log of the device, only when it receives
a sublog transmission instruction from Remote Monitoring Server.
Operation instruction Operation check
E-RDS contacts Remote Monitoring Server to check if there is processing to be
executed next, and receives the following instructions if any.
• Linkage with Software Distribution(CDS)
• Sublog transmission
Linkage with server RDS bit function
E-RDS sends data to the RDS server with an instruction from the RDS server.
Third party function
E-RDS sends data to the 3rd party server other than the Remote Monitoring Server.
Limitations
■ Servicing Notes
• After clearing the setting values in service mode (execution of COPIER > FUNCTION > CLEAR > MN-CON), it is necessary
to initialize the E-RDS setting (ERDS-DAT) and execute a communication test (COM-TEST). If they are not performed, the
transmission of counter data to Remote Monitoring Server may end in error.
In addition, all settings must be reconfigured after the replacement of storage.
• Do not change the values of the following service mode items unless otherwise instructed.
If they are changed, an error occurs in the communication with Remote Monitoring Server.
• Port number of Remote Monitoring Server
COPIER > FUNCTION > INSTALL > RGW-PORT
Default: 443
• URL for connecting to Remote Monitoring Server
COPIER > FUNCTION > INSTALL > RGW-ADR
Default: https://b01.ugwdevice.net/ugw/agentif010
NOTE:
If it is sent to China, change to the following URL.
Default: https://b01.ugwdevice.net.ugw2.canon.com.cn
• On the device with an expired Remote Monitoring Service contract, make sure to disable its E-RDS setting (E-RDS: 0).
8. Monitoring Function
143
Содержание imageRUNNER ADVANCE System V3.13
Страница 10: ...Authentication 2 Login Services 6 Management of the Authentication Method 11 Management of Users 17 ...
Страница 40: ...Firmware Management 4 Overview 36 Update Using Updater 47 Version Update Using Download Mode 70 ...
Страница 51: ...7 Restore the backed up setting values obtained in step 1 4 Firmware Management 46 ...
Страница 92: ...MEAP Application Management 6 About SMS 88 Settign Procedure 90 Maintenance 97 Troubleshooting 103 ...
Страница 120: ...5 Confirm that is displayed on the right side of the selected file and press 7 Backup Restoration 115 ...
Страница 146: ...Monitoring Function 8 E RDS 142 ...
Страница 155: ...APPENDICES Automatic Recovery Function 151 Special Startup 153 Backup List 159 Detail of Storage partition 175 ...
Страница 179: ...Not installed Flash PCB Backup List 174 ...