4
4-18
#SCAN
Setting of Scanner Functions (SCANNER)
Item1
No.
Initial
setting
Appropriate
guideline
Description
#SCAN SW
#SCAN
NUMERIC
001: - 032:
Not used
033:
50
Vertical scan magnification
correction (scanning on BOOK)
034:
50
Horizontal scan magnification
correction (scanning on BOOK)
035: - 046:
Not used
047:
50
Vertical scan magnification
correction (scanning on ADF)
048:
50
Horizontal scan magnification
correction (scanning on ADF)
049: - 192:
Not used
193:
0
0: LEGAL
1: FOOLSCAP
2: M_OFICIO
3: A_FOOLSCAP
4: FOLIO
5: G_LEGAL
6: A_OFICIO
7: B_OFICIO
8: OFICIO
9: E_OFICIO
ADF special paper, standardized
size: LGL
misidentification-ready
194:
0
0: LTR
1: G_LTR
2: A_LTR
ADF special paper, standardized
size: LTR
misidentification-ready
195:
0
0: LTR_R
1: FOOLSCAP
2: OFFICIO
3: E_OFFICIO
4: G_LTR_R
5: A_LTR_R
ADF special paper, standardized
size: LTR_R
misidentification-ready
196: - 290:
Not used
■
T-4-31
T-4-31
Item1
Item2
Item3
Item4
Initial
setting
Appropriate
guideline
Description
READER DISPLAY
CCD
TARGET-B
Target value of shading for blue
TARGET-G
Target value of shading for
green
TARGET-R
Target value of shading for red
OFST
Adjustment value of offset level
on CIS
OFST-B
not used
OFST-G
not used
OFST-R
not used
OFST-O
not used
OFST-E
not used
GAIN
Adjustment value of gain level
on CIS
GAIN-B
not used
GAIN-G
not used
GAIN-R
not used
GAIN-O
not used
GAIN-E
not used
IO
R-CON
Firmware version of reader
controller PCB
FEEDER
ROM version of DADF controller
PCB
ADJUST
ADJ-XY ADJ-X
20
1 to 211,
1=0.1mm
Adjustment of scanning system
image lead edge position
(image's scan-start position in
vertical scanning direction)
ADJ-Y
0
-25 to +25,
1=0.1mm
Adjustment value of image
scan-start position <Y-direction>
ADJ-S
75
25 to 500,
1=0.1mm
Adjustment of CCD/CIS scan-
start cell position (image scan-
start position in horizontal
scanning direction)
ADJ-Y-DF 0
-25 to +25,
1=0.1mm
Adjustment of horizontal
scanning position at feeder
mode
STRD-POS 100
1 to 200
Adjustment of CCD/CIS scan
position at stream-reading mode
with DF
ADJ-X-MG 0
-10 to +10,
1=0.1%
Fine adjustment of magnification
ration in vertical scanning when
scanning with reader copyboard
Содержание IMAGERUNNER 2530
Страница 9: ...1 1 Periodical Service Consumable Parts and Cleaning Parts ...
Страница 13: ...1 5 1 Cleaning Parts Fixing guide Transfer guide F 1 2 F 1 2 ...
Страница 14: ...2 2 Adjustment Overview Adjustment when replacing parts image position adjustment ...
Страница 20: ...3 3 Error Code Overview Error Code Jam Code Alarm Code ...
Страница 34: ...4 4 Service Mode Overview Details of Service Mode ...
Страница 85: ...5 5 Parts Replacement and Cleaning List of Parts ...
Страница 98: ...6 6 Product Overview Specifications Product lineups Basic Configuration ...
Страница 106: ...7 7 Version Upgrading Upgrading Targets and Procedure ...