4-13
4
<007: ATT transmission level>
Use it to set the transmission level (ATT).
Raise the transmission level if errors occur frequently at time of communication because of
the condition of the line. (It means close to 8)
MEMO:
Any of the following error codes may be indicated at time of transmission because of
the line condition:
##100, ##101, ##102, ##104, ##201, ##280, ##281, ##282, ##283, ##284, ##750,
##752, ##754, ##755, ##757, ##759, ##760, ##762, ##764, ##765,
##767, ##769, ##770, ##772, ##774, ##775, ##777, ##779, ##780, ##782, ##784,
##785, ##787, ##789
Any of the following error codes may be indicated at time of reception because of the
line condition:
##103, ##106, ##107, ##201, ##793
##103, ##106, ##107, ##201, ##793
<008: V.34 modulation speed upper limit>
Use it to set an upper limit to the modulation speed (baud rate) for the V.34 primary
channel.
<009: V.34 data speed upper limit>
Use it to set an upper limit to the data transmission speed for the V.34 primary channel
between 2.4K and 33.6K bps in increments of 2400 bps. (0: 2.4K to 13:33.6K bps).
<010: Frequency of the pseudo CI signal>
You may select a frequency for the pseudo CI signal.
Some types of external telephones do not ring when the fax/tel switch-over function is ON.
To sound the ring, change the pseudo CI signal.
●
●
●
●
#NUMERIC
Numerical Parameter Composition
No.
Item
Range of settings
002
RTN transmission condition(1)
1% to 99%
003
RTN transmission condition (2)
2 to 99 item
004
RTN transmission condition (3)
1 to 99 lines
005
NCC pause time length (pre-ID code)
1 to 60 sec
006
NCC pause time length (post-ID code)
1 to 60 sec
010
line condition identification time length
0 to 9999 (10 msec)
011
T.30T1 timer (for reception)
0 to 9999 (10 msec)
013
T.30 EOL timer
500 to 3000 (10 msec)
015
hooking detection time length
0 to 999
016
time length to first response at time of fax/tel switchover
0 to 9
017
pseudo RBT signal pattern ON time length
0 to 999
018
pseudo RBT signal pattern OFF time length (short)
0 to 999
019
pseudo RBT signal pattern OFF time length (long)
0 to 999
020
pseudo CI signal pattern ON time length
0 to 999
021
pseudo CI signal pattern OFF time length (short)
0 to 999
022
pseudo CI signal pattern OFF time length (long)
0 to 999
023
CNG detection level at time of fax/tel switchover
0 to 7
024
pseudo RBT transmission level at time of fax/tel switchover
10 to 20
0 to 20 (120/230V)
025
Answering machine connection function signal detection time
0 to 999
027
preamble detection time length for V21 low-speed flag
20 (x 10ms)
051
Hooking detection threshold
053
Setting of DTMF call origination count at remote reception of fax
054
Setting of busy tone output time when handset is used
055
acquisition period of environmental log data
0 to 480 (60min)
056
display the type of soft counter 1
101 (Fixed)
057
Display the type of soft counter 2
0 to 999
058
Display the type of soft counter 3
0 to 999
059
Display the type of soft counter 4
0 to 999
060
Display the type of soft counter 5
0 to 999
061
Display the type of soft counter 6
0 to 999
074
e-RDS RGW port number
075
Interval of transmission for e-RDS 3rd party
■
T-4-28
T-4-28
Содержание IMAGERUNNER 2530
Страница 9: ...1 1 Periodical Service Consumable Parts and Cleaning Parts ...
Страница 13: ...1 5 1 Cleaning Parts Fixing guide Transfer guide F 1 2 F 1 2 ...
Страница 14: ...2 2 Adjustment Overview Adjustment when replacing parts image position adjustment ...
Страница 20: ...3 3 Error Code Overview Error Code Jam Code Alarm Code ...
Страница 34: ...4 4 Service Mode Overview Details of Service Mode ...
Страница 85: ...5 5 Parts Replacement and Cleaning List of Parts ...
Страница 98: ...6 6 Product Overview Specifications Product lineups Basic Configuration ...
Страница 106: ...7 7 Version Upgrading Upgrading Targets and Procedure ...