4-7
4
SSSW-SW06
List of Functions
Bit
Function
1
0
0
not used
-
-
1
not used
-
-
2
not used
-
-
3
FAX stamp display setting
Displayed
Not displayed
4
original read width
LTR
A4
5
not used
-
-
6
not used
-
-
7
not used
-
-
Detailed Discussions of Bit 3
Select whether to display the stamp menu in the user menu after installation of the optional
stamp unit.
Detailed Discussions of Bit 4
Use it to select a read width for originals.
If ‘LTR’ is selected, the machine will read LTR originals at LTR width (214mm).
SSSW-SW012
List of Functions
Bit
Function
1
0
0
1-page time-out length for transmission
1
0
1
not used
-
-
2
1-page time-out length for transmission (HT
transmission)
1
0
3
not used
-
-
4
1-page time-out length for reception
1
0
5
not used
-
-
6
not used
-
-
7
page timer setting by transmission/reception
set
do not set
The machine will stop the ongoing communication if the transmission/reception of a single
original page takes 32 min or more. To use the timer for a purpose other than this function,
refer to the tables that follow, and select an appropriate time length.
When 'do not enable' is selected using bit 7, the time-out length for a single page for all
modes will depend on the setting of bit 0 and bit 1.
●
●
T-4-7
T-4-7
T-4-8
T-4-8
Time-Out Length for Transmission/reception
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
8min.
0
*
*
*
*
*
0
0
16min.
0
*
*
*
*
*
0
1
32min.
0
*
*
*
*
*
1
0
64min.
0
*
*
*
*
*
1
1
Time-Out Length for Transmission (text mode)
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
8min.
1
*
*
*
*
*
0
0
16min.
1
*
*
*
*
*
0
1
32min.
1
*
*
*
*
*
1
0
64min.
1
*
*
*
*
*
1
1
Time-Out Length for Transmission (image mode other than text mode)
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
8min.
1
*
*
*
0
0
*
*
16min.
1
*
*
*
0
1
*
*
32min.
1
*
*
*
1
0
*
*
64min.
1
*
*
*
1
1
*
*
Time-Out Length for Reception
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
8min.
1
*
0
0
*
*
*
*
16min.
1
*
0
1
*
*
*
*
32min.
1
*
1
0
*
*
*
*
64min.
1
*
1
1
*
*
*
*
SSSW-SW013
List of Functions
Bit
Function
1
0
0
not used
-
-
1
not used
-
-
2
Convert "inch" into "mm" when transmitting the
received image data
convert
do not convert
●
T-4-9
T-4-9
T-4-10
T-4-10
T-4-11
T-4-11
T-4-12
T-4-12
Содержание IMAGERUNNER 2530
Страница 9: ...1 1 Periodical Service Consumable Parts and Cleaning Parts ...
Страница 13: ...1 5 1 Cleaning Parts Fixing guide Transfer guide F 1 2 F 1 2 ...
Страница 14: ...2 2 Adjustment Overview Adjustment when replacing parts image position adjustment ...
Страница 20: ...3 3 Error Code Overview Error Code Jam Code Alarm Code ...
Страница 34: ...4 4 Service Mode Overview Details of Service Mode ...
Страница 85: ...5 5 Parts Replacement and Cleaning List of Parts ...
Страница 98: ...6 6 Product Overview Specifications Product lineups Basic Configuration ...
Страница 106: ...7 7 Version Upgrading Upgrading Targets and Procedure ...