7. Locking the Fixing Assembly
The locking between the film and the lower roller of the fixing assembly is designed to be released when
the front door is opened.
Operating the machine with the front door open for servicing work and, therefore, with the fixing
unlocked can displace the film. For this reason, you must always lock the fixing assembly as follows if you
need to operate the machine with its front door open.
Use the separation cleaning static eliminator cleaning brush attached behind the front door for locking.
Using the Separation Static Eliminator
Figure 3-647
If the fixing cover is absent, use this side.
(Figure 3-649)
If the fixing cover is present, use this side.
(Figure 3-648)
COPYRIGHT © 1996 CANON INC. CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
3–126
3. OPERATIONS AND TIMING
q
If the fixing assembly cover is found,
Insert the handle of the separation static elim-
inator cleaning brush as shown, and turn it
90° to fix in place, thereby locking the fixing
assembly.
Figure 3-648
w
If the fixing cover is not found,
Hold the cam stop arm so that it is parallel
with the front plate of the machine. Insert the
handle of the separation static eliminator
cleaning brush as shown into the gap on the
right of the cam stop arm, thereby locking the
fixing assembly.
Figure 3-649
Cam stop arm
Static
eliminator
brush
2
1
Static eliminator brush
Содержание GP200
Страница 8: ......
Страница 10: ......
Страница 42: ......
Страница 44: ......
Страница 54: ......
Страница 314: ......
Страница 324: ......
Страница 326: ......
Страница 366: ......
Страница 368: ......
Страница 412: ......
Страница 418: ......
Страница 458: ...PRINTED IN JAPAN IMPRIME AU JAPON 0796S2 82 1 This publication is printed on 70 reprocessed paper ...