Status Indications by Flashing LED
* The same error can occur when the fluorescent lamp has deteriorated over time or fails to turn ON. As
such, if the LED flashes at intervals of 6 sec, check to make sure that the inner side of the glass
around the filament at both ends of the fluorescent lamp has not become black.
3–75
COPYRIGHT © 1996 CANON INC. CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
3. OPERATIONS AND TIMING
Classification
Normal
Overcurrent
Low-voltage control
error in standby
Error in the commu-
nication with the DC
controller PCB
Low-voltage control
error during copying*
+5.1V output control
error
Check sum error on
the DC controller
PCB
Description
The composite power supply PCB is
operating normally.
The composite power supply PCB
has detected an overcurrent
because of trapped wiring or an
error in a load in relation to +24VR
or +24VU output.
The difference between the setting for
+24VR output and the control value in
standby is larger than specified.
Upon detection, error data is sent to
the DC controller PCB. ‘E803’ will be
indicated on the control panel.
An error has occurred in the commu-
nication between the DC controller
PCB and the composite power supply
PCB, and the communication data is
not renewed for 8 sec or more.
However, LED100 on the DC controller
may not flash or turn ON at times.
‘E191’ will be indicated on the con-
trol panel.
The difference between the setting
of the +24VR output and the actual
control value is more than specified.
Upon detection, error data will be
sent to the DC controller PCB.
‘E803’ will be indicated on the con-
trol panel.
+5.1V output is outside the specified
range. All outputs of the composite
power supply PCB will be stopped
so that the display indications on the
control panel will also turn OFF.
The CPU on the DC controller PCB
has detected a check sum error in the
communication data twice in a row.
All outputs of the composite power
supply PCB will be stopped.
‘E1921’ will be indicated on the con-
trol panel.
ON
OFF
0.5sec
0.5sec
ON
OFF
2sec
2sec
ON
OFF
3sec
3sec
ON
OFF
5sec
5sec
ON
OFF
6sec
6sec
ON
OFF
8sec
8sec
ON
OFF
10sec
10sec
Flashing intervals
Intervals of 2 sec
Intervals of 0.5 sec
Intervals of 3 sec
Intervals of 5 sec
Intervals of 6 sec
Intervals of 8 sec
Intervals of 10 sec
Содержание GP200
Страница 8: ......
Страница 10: ......
Страница 42: ......
Страница 44: ......
Страница 54: ......
Страница 314: ......
Страница 324: ......
Страница 326: ......
Страница 366: ......
Страница 368: ......
Страница 412: ......
Страница 418: ......
Страница 458: ...PRINTED IN JAPAN IMPRIME AU JAPON 0796S2 82 1 This publication is printed on 70 reprocessed paper ...