CANON Digital Galvano Scanner System
KP-1SM GC-251
Users Manual 1.00
80
Parameter ID
64
Parameter
Name
DSP Operation Setting
Data
DSP operation setting (Unit: none)
Return Value
0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter is used to set the activation mode. Each bit has a meaning.
Bit 0 0: No automatic encoder correction at homing to the origin
1: Automatic encoder correction at homing to the origin
Bit 1 0: Activation in internal clock mode
1: Activation in high-speed serial communication (external clock) mode
Bit 2 0: High-speed serial communication specification (XY2-100) (Usually 0)
Note: The setting is decimal.
Related
Command
/Parameter
Parameter ID
66
Parameter
Name
High Speed Serial Status Format
Data
High Speed Serial Status Format (Unit: none)
Return Value
0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
The content of status output to the status line of high-speed serial communications can
be selected.
1
:
Controller Condition
2
:
Current position (Axis 1)
3
:
Current position(Axis 2)
4
:
Current position(Axis1 , Axis2)
(For details, see 2.7.2, “High Speed Serial Communications”)
Related
Command
/Parameter
Parameter ID
67
Parameter
Name
High Speed Serial Data Length
Data
High Speed Serial Data Length (Unit: bit) Range = 16
〜
20
Return Value
0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
Position Data length of High speed serial communication can be specified.
Range = 16bit
〜
20bit
(For details, see 2.7.2, “High Speed Serial Communications”)
Related
Command
/Parameter