CANON Digital Galvano Scanner System
KP-1SM GC-251
Users Manual 1.00
6
2. Specifications
2.1.
Galvano Motor (KP-1SM30, KP-1SM100)
Performance and shape
KP-1SM30
KP-1SM100
Conforming
beam diameter
Φ
10 to
φ
20
Φ
20 to
φ
30
Scan angle
±20 deg
±20 deg
Number of encoder
pulses
83328 pulses/rotation
83328 pulses/rotation
Command resolution
0.036
μ
rad 0.036
μ
rad
Torque constant
0.041 Nm/A
0.093 Nm/A
Weight 0.95kg
1.65kg
(Reference) Command resolution
The controller of this system divides one encoder cycle into 2048.
KP-1SM30,SM100 is controlled by the following command resolution:
83328 pulses × 2048 divisions = 170655744 pulses/rotation (360°)
360°/ 170655744 = 0.000002109
°
= 0.036urad
Environmental conditions
Operating temperature and humidity
23
℃±
10
℃
, 80% RH or less (No condensation)
Storage temperature and humidity
–20 to 60
º
C, 90% RH or less (No condensation)
Note: The above operating temperature and humidity conditions depend on the operating and heat
radiation conditions.