(Target Position Data)
XDAT
、
YDAT
The data length of the target position data by the high-speed serial communication can be
changed by two following parameters.
The target position data length can be changed in 16bit – 20bit.
Parameter ID
DATA
67
16
:
16bit Data
※
17
:
17bit Data
18
:
18bit Data
19
:
19bit Data
20
:
20bit Data
The least significant bit position of the target position data of high-speed serial communication
20bit data can be set by following parameter.
The right shifts this number of bit make the target position data.
Parameter ID
DATA
68
0
:
0bit position
1
:
1bit position
※
2
:
2bit position
3
:
3bit position
4
:
4bit position
An example of the setting as follows.
Parameter ID = 67 16
Parameter ID = 68 1
Parameter ID = 67 18
Parameter ID = 68 2
(Bit)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
XDAT
C2
C1
C0
D15 D14 D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
P
YDAT
C2
C1
C0
D15 D14 D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
P
16bit
Data
(Bit)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
XDAT
D17 D16 D15 D14 D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
C1
C0
YDAT
D17 D16 D15 D14 D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
C1
C0
18bit
Data