Chapter 2
2-10
F-2-14
2.3.3 Original Size Detection 1
0011-2242
In original size detection 1, the original trailing edge sensor is used (S7), which is designed to identify the original in the original tray as being small-size or large-
size.
When the original covers the original trailing edge sensor, the light from the LED of the original trailing edge sensor is reflected by the original to hit the phototran-
sistor, at which time the DADF identifies the original as being large-size.
The DADF sends original size data (small-size or large-size) to the copier, which uses the data to determine the point at which the scanner is stopped for stream
reading.
Small size:
A5, A4, B5, STMT, LTR
Large-size:
A4R, B5R, A3, B4, LTRR, LGL, 279.4X431.8mm (11"X17")
ADF controller PCB
S6
(light-receiving side)
S6
(light-emitting side)
S6
(light-receiving side)
ADF controller PCB
When an original is detected
When no original is detected
S6
(light-emitting side)
S6
(light-receiving side)
ADF controller PCB
DTS signal
DTS signal
Original
Light is blocked.
S6
(light-emitting side)
Содержание DADF-Q1
Страница 1: ...Aug 24 2007 Service Manual Feeder DADF Q1 ...
Страница 2: ......
Страница 6: ......
Страница 11: ...Chapter 1 Specifications ...
Страница 12: ......
Страница 14: ......
Страница 18: ......
Страница 19: ...Chapter 2 Functions ...
Страница 20: ......
Страница 22: ......
Страница 75: ...Chapter 3 Parts Replacement Procedure ...
Страница 76: ......
Страница 107: ...Chapter 4 Maintenance ...
Страница 108: ......
Страница 149: ...Chapter 5 Error Code ...
Страница 150: ......
Страница 151: ...Contents Contents 5 1 Service Error Code 5 1 5 1 1 E402 5 1 5 1 2 E404 5 1 5 1 3 E405 5 1 5 1 4 E410 5 1 5 1 5 E420 5 1 ...
Страница 152: ......
Страница 154: ......
Страница 155: ...Aug 24 2007 ...
Страница 156: ......