7-90
COPYRIGHT © 2001 CANON INC. CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
c. E000=0002
You cannot clear ‘E005’ by executing ‘E005-RLS’ without replacing the web. Replace the web
first.
2
E005
3
E006
Cause
Triac (short
circuit)
DC controller
PCB
Step
1
Checks
Replace the triac. Is the problem
corrected?
Yes/No
YES
NO
Action
End.
Replace the DC controller
PCB.
Cause
Cleaning web
Counter
Detecting lever
(position)
Web length
sensor (PS36)
DC controller
PCB
Checks
Is the cleaning web more or less
used up?
After replacing the cleaning web, has
‘E005-RLS’ of ‘FUSER’ under
‘FUNC’ in service mode been ex-
ecuted?
Is the detecting lever of the web
length sensor on the web?
Is the web length sensor (PS36)
normal?
Yes/No
YES
NO
NO
NO
YES
Action
Replace the cleaning
web.
Execute ‘E005-RLS’ of
‘FUSER’ under ‘FUNC’ in
service mode.
Re-mount it.
Replace the web length
sensor.
Replace the DC controller
PCB.
Step
1
2
3
4
Cause
Fixing drawer
connector
DC controller
PCB
Step
1
Checks
Is there a fault in the fixing drawer
connector?
Yes/No
YES
NO
Action
Replace the drawer
connector.
Check the wiring from
J2209A on the DC con-
troller PCB to the fixing
drawer connector J6019;
if normal, replace the DC
controller PCB.
Содержание 1000S
Страница 12: ......
Страница 30: ......
Страница 44: ......
Страница 86: ......
Страница 254: ......
Страница 372: ......
Страница 374: ......
Страница 418: ......
Страница 438: ......
Страница 442: ......
Страница 754: ......
Страница 764: ......
Страница 766: ......
Страница 840: ...0501GR PRINTED IN JAPAN IMPRIME AU JAPON This publication is printed on 100 reprocessed paper ...