7-256
COPYRIGHT © 2001 CANON INC. CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
2. R-CON (reader controller PCB-related adjustment)
<M>
<S>
<R>
<P>
<F>
DISP
ADJUST
COUNTER
FUNC
RCON-1
xxxx
RCON-2
xxxx
RCON-6
RCON-3
xxxx
RCON-4
xxxx
RCON-5
xxxx
OPTION
TEST
RAM-CLR
CHK-SUM
R-CON
READY
1/2
Item
RAM-CLR
CHK-SUM
RCON-1
RCON-2
RCON-3
RCON-4
RCON-5
RCON-6
Description
Clears the RAM on the reader controller PCB and sets
the standard value.
Starts a check of the ROM on the reader controller
PCB, i.e., totals the RAM data.
Indicates the check sum value of Q1301 on the reader
controller PCB.
Indicates the check sum value of Q1305 on the reader
controller PCB.
Indicates the check sum value of Q1308 on the reader
controller PCB.
Indicates the check sum value of Q1312 on the reader
controller PCB.
Indicates the check sum value of Q1315 on the reader
controller PCB.
Reserved.
Remarks
The power switch will
automatically turn off
when ‘RAM-CLR’ is
executed. The contents of
the RAM are replaced
with the initial settings
when the power switch is
turned on thereafter.
During operation,
‘<R>READY
→
BUSY’.
Indicates only when
‘CHK-SUM’ is executed.
Содержание 1000S
Страница 12: ......
Страница 30: ......
Страница 44: ......
Страница 86: ......
Страница 254: ......
Страница 372: ......
Страница 374: ......
Страница 418: ......
Страница 438: ......
Страница 442: ......
Страница 754: ......
Страница 764: ......
Страница 766: ......
Страница 840: ...0501GR PRINTED IN JAPAN IMPRIME AU JAPON This publication is printed on 100 reprocessed paper ...