COPYRIGHT © 2001 CANON INC. CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
4-115
4. MECHANICAL SYSTEM
16. Removing the Image Position
Correction Pattern Reading CCD
Unit
1)
Remove the hopper left cover.
2)
Slide out the separation charging assembly
[1], and remove the screw [2] to remove the
CCD unit cover [3].
Figure 4-1101-16
3)
Slide out the transfer unit.
4)
Free the harness [5] from the three wire
saddles [4].
5)
Remove the screw [7], and remove the cable
support plate [6].
Figure 4-1102-16
6)
Disconnect the two connectors [8] from the
front.
7)
Remove the unit fixing screw [9], and remove
the image position correcting CCD unit [10].
Figure 4-1103-16
8)
Remove the two screws [12], and remove the
rear cable fixing plate [11].
9)
Disconnect the two connectors [13] from the
rear.
Figure 4-1104-16
After installing the image position
correction CCD unit, execute ‘FUNC
> INSTALL (2nd screen) > REG-
APER (auto adjustment of pattern
reading position)’; then, turn off and
then on the power to execute image
position correction.
[2]
[3]
[1]
[4]
[5]
[6]
[7]
[5]
[8]
[10]
[8]
[9]
[13]
[12]
[12]
[11]
Содержание 1000S
Страница 12: ......
Страница 30: ......
Страница 44: ......
Страница 86: ......
Страница 254: ......
Страница 372: ......
Страница 374: ......
Страница 418: ......
Страница 438: ......
Страница 442: ......
Страница 754: ......
Страница 764: ......
Страница 766: ......
Страница 840: ...0501GR PRINTED IN JAPAN IMPRIME AU JAPON This publication is printed on 100 reprocessed paper ...