4. MECHANICAL SYSTEM
4-62
COPYRIGHT © 2001 CANON INC. CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
2)
Check to make sure that the marking [1] on
the lens assembly matches the marking [2] on
the lens mount (standard position).
Figure 4-608A
If the unit is not in standard position, loosen
the locking nut [3], and turn the lens assembly until
the distance to the end [4] of the lens assembly is
27.3 ±0.2 mm, i.e., where the markings match.
Figure 4-609A
3)
Perform focusing adjustments by turning the
lens assembly once again according to the
values recorded on the label. For instance, if
the value is “+2/8,” turn the lens assembly in
the positive direction (counterclockwise when
viewing from the end of the lens assembly)
over two notches.
Figure 4-610A
Figure 4-611A
5)
Tighten the locking nut [3], and fix the position
of the lens in place.
[1]
[2]
27.3±0.2mm
[4]
[3]
8
R
FS6-8028
Protrusion label
Positive direction