5. Commissioning
.39.
.38.
5. Commissioning
2. The LCD screen will show that a password is required. The default password is "0010",
press the DOWN key to move cursor, press the UP key to change the highlig hted digit.
3. Use the UP/DOWN keys to highlight the SELECT STANDARD option. Press enter to
select.
Password
2015-02-23 19 35
Please Input The Current Password
X
X
X
X
E S C
U P
D O W N
E N T
Y E S
=
< E N T >
N O
=
< E S C >
Figure 5.3
Figure 5.4
Advanced
Set
.
2015-02-23 19 35
Grid
ON
/
OFF
Power Control
Clear
Energy
Restore
Settings
Restart
HMI
Calibrate
Reset
Password
Special Settings
STD.Mode Settings
External EPM set
Select
Standard
Select Standard
2015-02-23 19 35
Select
Standard
R21P3-480
E S C
U P
D O W N
E N T
Y E S
=
< E N T >
N O
=
< E S C >
Save
/
Cancel
2015-02-23 19 35
Save
&
Send
Cancel
&
Exit
Y E S
=
< E N T >
N O
=
< E S C >
4. Select the grid standard for the country of installation (see Figure 5.5).
Press the UP or DOWN key to select the standard (AS4777, VDE4105, R21P3-480, G59/3, CQC,
User-Def function, etc.). Press the ENTER key to confirm the setting. Press the ESC key to
cancel changes and return to the previous menu.
5. Once the grid standard has been selected, select SAVE AND SEND on the following
screen to save the new grid setting.
UL-480V is default setting for the U.S. markets.
UL-480V-A is the standard for inverters with AFCI function.
R21P3-480 is default setting for the U.S. markets.
R21P3-48A is the standard for inverters with AFCI function.
ISONE480A is available for New England region.
Figure 5.6
Figure 5.5