3. Installation
3. Installation
.17.
.16.
1) .
Installation of mounting wire box bracket:
Use 4 sets hexagon head bolts M4*40, flat
washer M10, nut M10 to attach the wire box bracket on the mounting rack. The tightening
torque is 17.6-22.1 ft-lbs.
Inverter mounting plate
Wire
box mounting plate
2) .
Installation of mounting Inverter bracket:
1.Put the inverter bracket onto the two M6 studs on the mounting rack, and use flange nuts to
tighten, the torque is 2.9 ft-lbs.
2.Use 2 sets of hexagon head bolts M4*40, flat washer 10, nut M10 to attach the inverter
bracket on the mounting rack. The tightening torque is 17.6-22.1 ft-lbs.
3.3.1 Installation
NOTE
If it is not installed on a faat wall, the inverter must be installed on a steel
rack, and the steel rack must meet the following requirements:
a. Inverter mounting rack must be in the same plane, the mounting rack
must not be twisted, bent or out of square, the flatness must be
≤
1 mm.
b. The mounting rack must be equal to or stronger than the marked rack
(40mm*60mm*2mm).
NOTE
Inverter must not be mounted on a
post or pole.
Damage to inverter or mounting bracket
may occur.
Inverter must be mounted on a frame as
shown or on a wall or other flat surface.