NOTE:
Currently, no logic in the program exists to turn off the heaters under a transducer failure or
any condition that would obscure the transducers and not be removed by heating. Both of
these conditions will appear as a signal blockage. This could result in a deep draining of a
power supply. If such logic is desired, please work with Campbell Scientific to add a timeout
into the code.
Table 7-7: CSAT3H heater controller outputs
Variable name
Units
Description
CSAT3H_user_ctrl_on_secs
s
The length of time in the output interval that CSAT3H_
user_ctrl_on was set to 1
CSAT3H_ctrl_on_secs
s
The length of time in the output interval that CSAT3H_
ctrl_on was set to 1
U_total_Avg
m/s
Total wind speed: an average over the last slow scan
intervals in the main data logger
Ts_Avg
°C
Average sonic temperature during the interval
diag_sonic_output_intv
–
Diagnostic word output by the sonic during the interval
press_Avg
hPa
Average ambient pressure during the interval
com_intv
s
Communication interval between the main data logger
and CSAT3H heater controller (for example., slow scan
interval in main data logger measurements)
T_trnsd_uppr_Avg
°C
Average temperature measured by the thermistor in the
elbow of the A' (top) sonic finger
T_trnsd_uppr_Std
°C
Temperature standard deviation measured by the
thermistor in the elbow of the A' (top) sonic finger
T_trsnd_lwr_Avg
°C
Average temperature measured by the thermistor in the
elbow of the A (bottom) sonic finger
T_trnsd_lwr_Std
°C
Temperature standard deviation measured by the
thermistor in the elbow of the A (bottom) sonic finger
T_trsnd_Max
°C
Maximum temperature between the top and bottom
transducers
T_trsnd_Min
°C
Minimum temperature between the top and bottom
transducers