NOTE:
A CSAT3BCBL1 may also be used for power, but the SDM wires will not be used. The
CSAT3BCBL1 also has lighter gauge power wires, which increases voltage loss over long cable
lengths, so it should only be used for shorter cable lengths.
Connect the 5 m (16 ft) USB cable included with the CSAT3BH to the USB port in the same way. If
only one CSAT3BH is being measured, the opposite end of the power cable should have pigtail
wires, which may be connected to a 9.5 to 32 VDC power supply, and the USB cable should be
connected to a USB port on a computer.
For a watertight connection to the USB port, use the included USB cable. For a temporary, non-
watertight connection to the USB port, any USB type A pin to type mini-B pin cable can be used.
WARNING:
Unused ports on the CSAT3BH block should always be covered securely by the caps to avoid
water damage to the electronics.
If a fine-wire thermocouple such as a model FW05 with FWC-L is being used, the wiring
designations in
(p. 60) should be followed to connect the thermocouple to a
differential voltage terminal on a data logger.
Table 6-8: FW05/FWC-L fine-wire thermocouple
Description
Color
Signal high
Purple
Signal low
Red
6.11 Confirm CSAT3BH factory settings
The CSAT3BH is shipped from the factory with the default settings that are shown in
61). These settings can be changed with a computer running Campbell Scientific
Device
Configuration Utility
, version 2.10 or newer, and the USB cable that ships with the CSAT3BH.
Device Configuration Utility
is available from the Campbell Scientific website at
and is included with
LoggerNet
and
PC400
software
packages.
CSAT3BH Three-Dimensional Heated Sonic Anemometer
60