59
Scanner
®
2000 microEFM
Section 2
Table 2.2—Industry Standards for Orifice Meters
Standard
Applicable Section Description
Notes
AGA Report No. 3:
Orifice Metering of
Natural Gas and Other
Related Hydrocarbon
Fluids
Part 2: Specification
and Installation
Requirements,
Section 2.6
(Installation
requirements)
Specifications for orifice
meters (to include beta ratios)
Installation requirements for
orifice plates, meter tubes, flow
conditioners, and thermometer
wells
This standard is also
distributed under the
following names: API
MPMS Chapter 14.3, Part
2; ANSI/API 14.3, Part
2-2000; and GPA 8185,
Part 2.
ISO 5167:
Measurement of Fluid
Flow by Means of
Pressure Differential
Devices Inserted in
Circular Cross-Section
Conduits Running Full
Part 1: General
Principles and
Requirements
Installation of orifice plates
inserted into a circular cross-
section conduit running full
Limitation of pipe size and
Reynolds number
ISO 5167 is applicable
only to flow that remains
subsonic throughout the
measuring section and
where the fluid can be
considered single-phase.
It is not applicable to the
measurement of pulsating
flow. It does not cover the
use of orifice plates in pipe
sizes less than 50 mm
(2 in.) or more than 1000
mm (39 in.), or for pipe
Reynolds numbers below
5000.
ISO 5167:
Measurement of Fluid
Flow by Means of
Pressure Differential
Devices Inserted in
Circular Cross-Section
Conduits Running Full
Part 2: Orifice
Plates
Specifies orifice plates that can
be used with flange pressure
tappings, corner pressure
tappings, D and D/2 pressure
tappings.
API Manual
of Petroleum
Measurement
Standards, Chapter
21.1 (Electronic Gas
Measurement)
Section 1.7
-Equipment
Installation
Installation of electronic gas
measurement devices and
associated communications,
gauge/impulse lines, and
cabling
Section 1.8
-Equipment
Calibration and
Verification
Requirements for calibrating
and verifying the accuracy of
electronic gas measurement
devices
Industry Standards for Cone Meters
For installation requirements for use with a cone meter and applicable flow rate calculations, see the NuFlo
Cone Meter User Manual, Part No. 9A-85165000.
Содержание Scanner 2000 microEFM
Страница 1: ...NUFLO Scanner 2000 microEFM Hardware User Manual Manual No 9A 30165023 Rev 10 ...
Страница 26: ...26 Section 1 Scanner 2000 microEFM ...
Страница 104: ...A 18 Appendix A Scanner 2000 microEFM ...
Страница 106: ...B 2 Appendix B Scanner 2000 microEFM ...
Страница 188: ...E 10 Appendix D Scanner 2000 microEFM ...
Страница 190: ...R U S S I A 603 5569 0501 ms kl c a m com ...