45
Scanner
®
2000 microEFM
Section 2
d. Connect a hand pump or funnel to the fitting.
e. Pour fill liquid into the funnel or pump it into the cold leg, tapping the cold leg occasionally to dis
-
lodge any bubbles.
f. Observe the pipe tee/condensate pot and stop pouring when the fill liquid is visible at the top and no
air bubbles can be seen.
g. Remove the fitting from the vent of the MVT and quickly replace the vent screw and tighten.
h. Close the blowdown valve or replace the filling plug from one of the pipe tees/condensate pots.
i. Repeat steps a through h for the other cold leg.
9.
To eliminate an offset of the differential pressure reading, open the equalizer valves on the block manifold,
remove the caps from the seal pots, and adjust either seal pot vertically to bring the water levels to the exact
same elevation.
10.
Perform a manifold leak test as described on
11. Verify the zero offset, if required (and other calibration points, if desired). See the ModWorX™ Pro Soft
-
ware User Manual, Part No. 9A-30165025, for complete instructions. See also
or Differential Pressure), page 56, Static Pressure Calibration and Verification, page 56
sure Calibration and Verification, page 57
CAUTION Do not put the Scanner into operation until the valves are positioned properly so that
pressure is supplied to both sides of the MVT. For instructions on proper valve positions,
see
Placing the Scanner into Operation, page 58
.
Содержание Scanner 2000 microEFM
Страница 1: ...NUFLO Scanner 2000 microEFM Hardware User Manual Manual No 9A 30165023 Rev 10 ...
Страница 26: ...26 Section 1 Scanner 2000 microEFM ...
Страница 104: ...A 18 Appendix A Scanner 2000 microEFM ...
Страница 106: ...B 2 Appendix B Scanner 2000 microEFM ...
Страница 188: ...E 10 Appendix D Scanner 2000 microEFM ...
Страница 190: ...R U S S I A 603 5569 0501 ms kl c a m com ...