Table E.1—Resource Block Parameters
Index
Parameter
Definition
435
UPDATE_EVT
Alert generated by any change to the static data
436
BLOCK_ALM
Alarm used for all configuration, hardware, connection failure or
system problems in the block. The cause of the alert is entered in
the subcode field.
437
ALARM_SUM
Current alert status, unacknowledged states, unreported states,
and disabled states of alarms associated with the function block.
438
ACK_OPTION
Selection of whether alarms associated with the block will be
automatically acknowledged
439
WRITE_PRI
Priority of the alarm generated by clearning the write lock.
440
WRITE_ALM
This alert is generated if the write lock parameter is cleared.
441
ITK_VER
Major revision number of the interoperability test case used in
certifying this device as interoperable.
442-464
Field Diagnostics
NOTE: Field Diagnostics (FD) parameters are not currently
supported.
Table E.2—Transducer Block Parameters
Relative
Parameter
Definition
2000
NAME
Block name and record member Information
2001
ST_REV
Revision level of the static data associated with the function block
2002
TAG_DESC
User description of the intended application of the block
2003
STRATEGY
Group identification number of the block
2004
ALERT_KEY
Identification number of the plant unit
2005
MODE_BLK
Mode of function block (ACTUAL, TARGET, PERMITTED, AND
NORMAL)
2006
BLOCK_ERR
Error status on hardware or firmware components related to this
block
2007
UPDATE_EVT
Alert generated by any change to the static data
2008
BLOCK_ALM
Alarm used for all configuration, hardware, connection failure or
system problems in the block. The cause of the alert is entered in
the subcode field.
2009
TRANSDUCER_
DIRECTORY
Specifies the number and starting indicies of the transducers in
the transducer block
2010
TRANSDUCER_TYPE
Type of transducer block
2011
XD_ERROR
Error code for transducer error
2012
COLLECTION_
DIRECTORY
Specifies the number, starting indicies, and DD Item IDs of the
data collections in each transducer within a transducer block.
2013
PV_VALUE
Value of Primary value parameter and its status
2014
PV_UNIT
Enumerated unit for Primary value
2015
SV_VALUE
Value of Secondary value parameter and its status
2016
SV_UNIT
Enumerated unit for Secondary value
2017
TV_VALUE
Value of Tertiary value parameter and its status
Содержание Scanner 2000 microEFM
Страница 1: ...NUFLO Scanner 2000 microEFM Hardware User Manual Manual No 9A 30165023 Rev 10 ...
Страница 26: ...26 Section 1 Scanner 2000 microEFM ...
Страница 104: ...A 18 Appendix A Scanner 2000 microEFM ...
Страница 106: ...B 2 Appendix B Scanner 2000 microEFM ...
Страница 188: ...E 10 Appendix D Scanner 2000 microEFM ...
Страница 190: ...R U S S I A 603 5569 0501 ms kl c a m com ...